di <integer> 6/6 Indicate which di detected.
This field is required when trigger
condition is “di”.
One bit represents one digital input. The
LSB indicates DI 0.
mdwin <integer> 6/6 Indicate which motion detection windows
detected.
This field is required when trigger
condition is “motion”
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 <integer> 6/6 Indicate which motion detection windows
of profile 1 is detected.
inter 1~999 6/6 Interval of period snapshot in minute.
his field is used when trigger condition is
“seq”.
weekday <interger> 6/6 Indicate which weekday is scheduled.
One bit represents one weekday.
The bit0 (LSB) indicates Saturday.
The bit1 indicates Friday.
The bit2 indicates Thursday.
The bit3 indicates Wednesday.
The bit4 indicates Tuesday.
The bit5 indicates Monday.
The bit6 indicates Sunday.
For example, to detect events on Friday
and Sunday, set weekday as 66.
begintime hh:mm 6/6 Begin time of weekly schedule.
endtime hh:mm 6/6 End time of weekly schedule.
(00:00 ~ 24:00 means always.)
lowlightcondition 0, 1 6/6 0 => Do action at all times
1 => Do action in low-light conditions
action_do_i<0~(nd
o-1)>_enable
0, 1 6/6 To enable or disable trigger digital output.
action_do_i<0~(nd
o-1)>_duration
1~999 6/6 The duration of digital output is triggered
in seconds.
action_cf_enable 0. 1 6/6 To enable put media on CF.