671884
23
Zoom out
Zoom in
Vorherige Seite
1/32
Nächste Seite
23
22
3. FOR THE USER
3.1 Commissioning
Warning
Installing and commissioning (for the
first time) of this water heater should
only be carried out by a qualified
competent heating engineer.
3.1.1 Filling the water heater
1. Close the drain tap.
2. Open the cold water tap to the water
heater and open all taps where hot
water can be drained for de-
aeration. The water heater is filled
as soon as cold water flows from all
taps.
3. Close all hot water drain taps.
3.1.2 Putting into operation
1. Check whether the device has been
filled with water and whether the
gas supply to the water heater is
open.
2. Turn the temperature control knob
clockwise and place the control knob
in the ‘PILOT’-position ().
3. Remove the outer and inner door of
the combustion chamber.
4. Keep the control button pushed-in
and press the piezo-ignitor several
times until the pilot burns (see Figure
6).
5. Keep the control button () pushed-
in for approximately 20 seconds.
After releasing the button the pilot
should remain burning. If the pilot
extinguishes you should wait 5
minutes before repeating the ignition
procedure.
6. Subsequently remount the inner and
outer door; see “Mounting the inside
door”.
7. Turn the control button to the ‘ON’
(
) position.
8. Place the temperature control button
in the correct position, preferably
position 4 (approximately 60°C). The
appliance will now operate fully
automatically.
3.1.3 Use
The appliance is under water supply
pressure (with a maximum of 8 bar).
The amount of cold water that is added
is equal to the amount of hot water
used. The gas control block
automatically regulates the gas supply.
The main burner will ignite as soon as a
reduction in water temperature is
sensed by the control thermostat. The
main burner will shut down as soon as
the water temperature returns to the
preset temperature.
Position 1 = approximately 30°C
Position 2 = approximately 40°C
Position 3 = approximately 50°C
Position 4 = approximately 60°C
Position 5 = approximately 70°C
Higher water temperatures will cause
more scale build up in the appliance. It is
for this reason that it is recommended to
place the temperature control knob in
position 4 as the accumulation of scale
will be reduced at lower temperatures.
In addition a safety thermostat has been
fitted. This thermostat completely shuts
off the gas supply if the water
temperature reaches 82°C, also
extinguishing the pilot burner.
3.1.4 Putting out of operation
1. For short periods of time the control
knob should be turned to (); the
pilot keeps burning.
2. For longer periods of time the knob
should be turned to the (
) position;
the pilot is extinguished.
3. Close the gas tap in the supply pipe.
In case of longer interruptions or in
the event of risk of frost it is
recommended to also close the cold
water tap and to drain the appliance
after cooling (open the drain tap; it is
possible to connect a drain hose to
the drain tap; open the nearest hot
water drain point to prevent
airlocks).
To be able to drain the appliance
completely it should be disconnected
23

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für A.O. Smith EQ 155 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von A.O. Smith EQ 155

A.O. Smith EQ 155 Bedienungsanleitung - Deutsch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info