5 - INSTALLATION
must supply and install a device that will shut-off the
appliance before the system materials maximum operating
temperature and pressure are met.
In gures 5-2 and 5-3 the service and maintenance valves
are not shown. Hydraulic and gas connections should
be tted with isolation valves to accomodate service and
maintenance works.
5.6 - Gas
CAUTION !!! It is prohibited to operate the
appliance with the incorrect gas type. Check the data
label on the appliance for Natural gas or Propane gas
to ensure that the correct appliance in being installed.
CAUTION !!! Check that the gas and supply
pressure are those for which the appliance has been
adjusted.
Two situations are possible:
A - the gas and supply pressure correspond to the
adjustment of the appliance. In this case, it can be
connected;
B - the gas and supply pressure do not correspond to the
adjustment of the appliance. In this case, the appliance
must be converted to the type of gas and supply
pressure corresponding to those of the supply available.
The appliance is provided with the relevant gas conversion
kit.
Before the gas appliance is installed it is essential to
ensure that the internal gas pipe is clean and free of
metal or plastic lings or any other solid pieces or liquids;
A manual shut-off valve must be installed on the gas
supply pipe adjacent to the appliance;
CAUTION !!! Before supplying gas to the
appliance, it is essential that the gas pipes have been
pressure tested in accordance with the most recent
applicable gas standards.
to prevent damage to the appliance gas valve, the
supply pressure should not exceed 50 mbar under any
circumstances;
if the gas pipe-work must be tested in excess of 50
mbar, ensure that the appliance is fully isolated.
Figures 5-2 and 5-3 shows the position and the diameter of
the gas connection on the appliance. Ensure that the gas line
is adequately sized to provide the maximum volumeow rate
at the required minimum pressure.
5.7 - Condensate drain
There is a siphon inside the appliance for the evacuation
of condensate (see gures 3-2 and 3-4 detail “40”) and to
prevent combustion products from escaping, whose end
corresponds to the pipe “9” in gure 5-5. This termination
must be conveyed into an anti-odour siphon (gure
5-5 detail “5”) to prevent bad odours returning into the
environment.
The condensate discharge must comply with the following:
it must be connected to the waste disposal plant by
Figure 5-4 - Appliance wall xing detail
1 - Cap (NOT TO BE USED)
2 - 1” D.H.W. outlet
3 - 3/4” gas inlet
4 - 1” cold water inlet
5 - Flue/Air intake
6 - Support attachments
Figure 5-3 - Dimensions and connections ICW 60
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für A.O. Smith Instano ICW 25 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von A.O. Smith Instano ICW 25

A.O. Smith Instano ICW 25 Bedienungsanleitung und Installationsanweisung - Holländisch - 64 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info