[36] CLX-CodeLoxx: Installation Operation Manual: V01 - (Art.-No. 800050)
22. Switching to ARMED, DISARMED, opening with ABUS evaluation units
Switching to DISARMED and opening is possible with any valid locking medium. The locking medium must also
be authorised in the evaluation unit when using AE255F.
If the burglar alarm centre (EMZ) switches to DISARMED after the end of authorisation input, this will be
confirmed by a short period of green flashing (= positive acknowledgement). This positive acknowledgement can
take place immediately after the end of input or - depending on the EMZ - after up to 10 seconds of delay.
Now the system is unlocked for 6 seconds (for multi-door applications without EMZ state feedback, the unlocking
only occurs after a delay interval set out in the configuration of the AEBasic). No adjustment of the delay period is
possible when using AE255F.
Various operating modes and special functions are possible depending on the configurations and products used.
Please refer to the instructions for evaluation devices AEBasic or AE255F.
22.1 Switching to ARMED or DISARMED with CLX and evaluation unit AE255F or AEBasic.
The CLX can be operated with a locking medium or 6-digit code.
Switch to DISARMED