Installation
21 | EN
Step 4: Power supply
Insert the batteries into the bracket, ensuring the polarity is correct.
Step 5: Program detector into alarm panel or receiver component
The following describes direct programming on the Secvest alarm panel
FUAA50000. For web-based programming and programming to other receivers,
please read the relevant chapter in the instructions about these components.
If this has not been done already, switch the alarm panel on.
Select:
Installer mode -> Components -> Detector -> Wireless zones -> Add/Remove detector
Choose a free wireless zone. The message ‘Activate the tamper contact of the detector’ is
displayed.
Flick the tampering switch.
The detector will then send a pairing signal to the alarm panel. The alarm panel will recog-
nise the detector.
Once the pairing signal has been received by the wireless alarm system, it will emit two
beeps. The message ‘Detector was programmed to: zone 2xy’ and the incoming signal
strength are displayed.
Confirm the successfully completed pairing on the control panel.
Step 6: Test the system
Test the system fully.
Signal strength
Installer mode > Test > Signal strengths > Detector
After selecting the signal strengths for all detectors is displayed on the alarm panel. For more de-
tails, please refer to the relevant instructions for the alarm panel or wireless extension.
Walk test
Installer mode > Test > Walk test
After making the selection, you can choose whether to test all detectors in the system, in a parti-
tion of the system, or individual detectors. For more details, please refer to the relevant instructions
for the alarm panel or wireless extension.