Appendix IV – Wiring Information
98
1.21 Transistor outputs
By programming the transistor outputs, you can
address external devices such as LEDs,
signalling devices and relays. The board contains
2 negative-switching outputs (–3 and –5) that
switch from 12V to 0V on activation, and a
positive-switching output (+4) that switches from
0V to 12V on activation. A current of up to 500mA
can flow through outputs –3 and –5. If output +5
is activated, it supplies a maximum current of
500mA for addressing external devices. The
outputs can be used for displaying intrusion,
panic, duress, voltage loss or input of a special
code.
1.22 Relay outputs
The two relay outputs have potential-free
alternating contacts, which can switch on/off
externally connected devices. Connect one
contact of a device with the COM contact and the
other either with N/O or N/C. If you connect to
N/O, the contact between COM and N/O is open
(N/O = normally open). If you use contact N/C,
the contact between COM and N/C is closed
(N/C = normally closed). Connect as shown here:
1.23 Relay module
For the digital communication outputs, you can
optionally use a relay board. You can switch max.
1A/30V DC with this.
1.24 Connecting strip: factory defaults
If the FACTORY RESTART contacts are short-
circuited while the alarm centre is connected to
the mains power supply, all system parameters
are reset to their factory default settings,
including the engineer password. Make sure the
contacts remain closed until LED1 begins to flash.
To reset the engineer password only, short-circuit
the two contacts briefly while the equipment is
connected to the mains power supply.
1.25 Serial printer interface
You can connect a serial printer (RS232) direct to
the alarm centre at the serial printer interface.
This enables you to print the programmed
settings or the event memory, including online. In
online mode, every event is printed immediately.
The printer settings are: 4800 baud, 8 data bits, 1
stop bit, 1 start bit, no parity, and DTR normal.
1.26 Engineer keypad
An operating panel set to “Engineer Keypad” can
be connected direct to the “ENGINEERS
KEYPAD” contacts of the alarm centre. This
operating panel should be connected only briefly,
for programming and testing. No tamper alarm is
generated when the engineer keypad is removed.
After the system has been completely
programmed, an engineer keypad should only be
connected to bus 1 or 2 for programming
purposes. Connect as in the following diagram:
1.27 Alarm centre LEDs
The LEDs have the following meaning:
LED1 (heartbeat): Flashes once a second
and shows that the alarm centre is
operational. Following a reset, the LED
flashes faster.
LED2 (bus fuse 1): Monitors bus 1. When lit,
shows that the 12V supply of the circuit is
open.
LED3 (bus fuse 2): Monitors bus 2. When lit,
shows that the 12V supply of the circuit is
open.
LED4 (telephone): Lights when the telephone
line is activated.
LED5 (voltage): Lights when the alarm centre
is supplied with voltage (mains or battery).
LED6 (12V output fuse): Monitors the fuse for
the 12V output for the connection of the
voltage supply of external devices.
LED7 (bell output fuse): Monitors the fuse of
the bell output.
LED8 (state of relay 1): Lights when relay 1 is
activated.
104

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Abus Terxon LX - AZ4200 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Abus Terxon LX - AZ4200

Abus Terxon LX - AZ4200 Installationsanweisung - Deutsch - 31 seiten

Abus Terxon LX - AZ4200 Bedienungsanleitung - Deutsch - 16 seiten

Abus Terxon LX - AZ4200 Bedienungsanleitung - Englisch - 16 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info