624424
52
Zoom out
Zoom in
Vorherige Seite
1/94
Nächste Seite
52 Copyright © Acronis, Inc., 2000-2010
To repair RAID-5 volume
1. Click the RAID-5 volume you need to repair, and then click Repair RAID. The RAID-5 volume
whose member has failed is in the Data Redundancy status.
2. Select the target disk where the reconstructed data will reside. The unallocated space on the
target disk has to be at least the size of the RAID-5 volume member. If you select a basic disk, it
will be automatically converted to dynamic.
3. Click OK to add the pending repairing RAID-5 volume operation.
The results of the pending operation are immediately displayed as if the operation had been
performed.
To perform the pending operation you will have to commit it (p. 24). Exiting the program without
committing the pending operations will effectively cancel them.
Important! If this operation was performed with machine rebooting or by using bootable media, the dynamic
volume will get the Failed redundancy status after booting into any edition of Windows 2003. To repair the
dynamic volume, reactivate the underlying disks by using Windows Disk Management functionality see the
Troubleshooting Disk Management article on the Microsoft Web site.
6.26 Specifying i-node density
This operation applies to volumes whose file systems are Ext2 or Ext3.
The i-node is the main data structure for Linux Ext2/Ext3. All of a files information, with the
exception of its actual name and data, is stored in the i-node. Each file has its own i-node. Each i-
node contains a file description, including number, file type, size, data block pointers, etc. Space for i-
nodes is allocated when you install the operating system or when a new file system is created. The
maximum number of i-nodes, and hence the maximum number of files, is set at file system creation.
Running out of i-nodes prohibits the creation of additional files and directories on the volume even if
there is sufficient disk space. I-nodes themselves consume disk space, so specifying the i-node
density lets you organize disk space in the optimal way. I-node density is determined by specifying
the number of bytes per i-node. Usually, the default value is 4096 bytes per i-node.
Important: If you change the i-node density of a boot volume the operating system will become unbootable. To
restore the system bootability use a boot loader.
To specify i-node density
1. Right-click the Ext2/Ext3 volume, and then click Change i-node density.
2. In Bytes per i-node, specify the required value.
Use lower i-node density (that is, increased Bytes per i-node value) for a volume that
contains just a few large files. This will allocate more space for files and less for i-nodes. The
less i-nodes there are the in the system, the faster the “file system check” operation will be
performed.
Use higher i-node density (that is, reduced Bytes per i-node value) for volumes that contain a
large number of small files. This will allocate more space for i-nodes and less for data. The
more i-nodes there are in the file system, the less likely you will not run of i-nodes. But, the
“file system check” operation will be performed slower.
3. Click OK to add the pending i-node density changing operation.
The results of the pending operation are immediately displayed as if the operation had been
performed.
52

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Acronis Disk Director 11 Advanced Server wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Acronis Disk Director 11 Advanced Server

Acronis Disk Director 11 Advanced Server Bedienungsanleitung - Deutsch - 103 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info