PRESET CONFIGURATION 1  PRESTIGE SOLO/EXCELLENCE 3WAY VALVE
DHW
CH1
CH2
Prestige
P3
P4
Two heating circuits, with two room thermostats and optional outdoor sensor,
and with DHW circuit.
Electrical board terminals Terminal name --> Connected to
ACV Max
123456
1 2 3 4 5 6
W
W
W
W
W
W
4 5 6
1 2 3
1 2 3
4 6
X15
1 2 3 4 5 6 7 8 9 10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X11
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
16
15
3 4
1 2
X16
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
W
R
Or
Bk
Bk
V
Bk
42 1 3 2 1 1 2 3 1 2 3 4 5 6
8 9 10 11 12
1 2 3 4 5
13
6
14
7
X2
1 2 3 4 5 6 7 8 9 10
W
R
Y
R
Y
BK
BK
W
6 7 8 9 10
1 2 3 4 5
X3
1 2 3 4 5 6 7 8 9 10 11 12
V
W
R
Bk
7 8 9 10 11
1 2 3 4 5
12
6
X1
R
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Y
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
V
1 2 3 4 5
1 2 3 4 5
8
Bk
2 31
1412 13
X12
X9
P14
123
4
123
456
B
V
B
W
P13
B
Or
123
Bk
B
Y/Gr
W
Br
B
Br
Br
Y/Gr
B
B
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
123
5
F00
X100
N
L
N
L
W
ON / OFF
3
230 V ~ 50Hz
1
N
L
N
L
N
L
2
6
B
Y/Gr
Br
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
V
B
Y/Gr
W
B
Y/Gr
Br
B
Y/Gr
Br
B
Y/Gr
B
Or
Br
B
Br
Y/Gr
B
X101
18
17
20
19
21
24
4
X10
12
X20
16
25
2 1
1
NTC 5
9
2 1
1
NTC 2
10
2 1
1
NTC 1
11
123
1
21234123456
X7
X4
X6
X5
Bus A
Bus - Ground
Bus B
0-10 Volt - Ground
0-10 Volt - Input
Cascade sensor - Ground
Cascade sensor - Input
NTC 3
NTC 4
1
2
22
23
26
X18
V
W
B
W
B
B
9 10 11 12 13 14 15 16
16 15 14 13 12 11 10 9
X100
7
Y/Gr
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4 P3
FL
27
5AT Fuse
5AT Fuse
5AT Fuse
............. ERR --> Error (Alarm)
............. DHW --> None
............. CH --> Built-in circulator pump
............. P4 --> P4 pump (CH2 circuit)
............. Flame --> Flame sensor
............. P3 --> P3 pump (CH1 circuit)
ACV Max
1 2 3 4 5 6
W
W
W
W
W
W
B
Br
4 5 6
1 2 3
1 2 3
4 6
1 2 3 4 5
X15
1 2 3 4 5
1 2 3 4 5 6 7 8 9 10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X11
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
18
17
3 4
1 2
X16
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
W
R
Or
Bk
Bk
Or
Bk
4 3 2 1 1 2 3 1 2 3 4 5 6
8 9 10 11 12
1 2 3 4 5
13
6
14
7
X2
1 2 3 4 5 6 7 8 9 10
W
R
Y
R
Y
W
6 7 8 9 10
1 2 3 4 5
X3
1 2 3 4 5 6 7 8 9 10 11 12
V
W
Br
R
Br
Or
B
W
R
Bk
7 8 9 10 11
1 2 3 4 5
12
6
X1
Bk
2 31
1615
X12
X9
P14
12
X10
12 3
4
123
456
B
B
V
B
W
W
B
B
P13
B
Or
123
Bk
B
Y/Gr
W
Br
B
Br
Y/Gr
B
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
123456
123
5
F00
X100
W
ON / OFF
3
230 V ~ 50Hz
1
2
6
26
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
V
B
Y/Gr
W
B
Y/Gr
Br
B
Y/Gr
Br
B
Y/Gr
B
Or
Y/Gr
19
21
20
22
23
24
4
B
W
V
Br
X20
25
X18
STEPPER
PUMP PWM
8
9
5AT Fuse
5AT Fuse
5AT Fuse
R
Bk
Y
Y
R
R
W
W
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
W
Or
Br
R
Br
B
Br
B
Y/Gr
V
1 2 3 4 5
1 2 3 4 5
10
A B C D 2 1
1
NTC 5
11
2 1
1
NTC 2
12
2 1
1
NTC 1
13
26
C
M
M
3 2 1 3 2 1
230 V
Bk
Bk
14
Bk
Bk
123
1
21234123456
X7
X4
X6
X5
Bus A
Bus - Ground
Bus B
0-10 Volt - Ground
0-10 Volt - Input
NTC 3
NTC 4
1
2
V
W
B
W
B
B
9 10 11 12 13 14 15 16
X100
7
Y/Gr
Y/Gr
16 15 14 13 12 11 10 9
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4 P3
FL
230 V
............. DHW sensor (NTC3)
............. Optional outdoor temp. sensor (NTC4)
............. Optional room thermostat 1
............. Optional room thermostat 2
ACV Max
123456
1 2 3 4 5 6
W
W
W
W
W
W
4 5 6
1 2 3
1 2 3
4 6
X15
1 2 3 4 5 6 7 8 9 10
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
X11
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
16
15
3 4
1 2
X16
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
W
R
Or
Bk
Bk
V
Bk
42 1 3 2 1 1 2 3 1 2 3 4 5 6
8 9 10 11 12
1 2 3 4 5
13
6
14
7
X2
1 2 3 4 5 6 7 8 9 10
W
R
Y
R
Y
BK
BK
W
6 7 8 9 10
1 2 3 4 5
X3
1 2 3 4 5 6 7 8 9 10 11 12
V
W
R
Bk
7 8 9 10 11
1 2 3 4 5
12
6
X1
R
Bk
Y
Y
Bk
Bk
R
R
W
W
V
Y
Bk
Bk
R
Bk
W
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
W
W
W
W
W
W
W
V
1 2 3 4 5
1 2 3 4 5
8
Bk
2 31
1412 13
X12
X9
P14
123
4
123
456
B
V
B
W
P13
B
Or
123
Bk
B
Y/Gr
W
Br
B
Br
Br
Y/Gr
B
B
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
123
5
F00
X100
N
L
N
L
W
ON / OFF
3
230 V ~ 50Hz
1
N
L
N
L
N
L
2
6
B
Y/Gr
Br
B
Y/Gr
Br
Br
B
Bk
B
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
Y/Gr
V
B
Y/Gr
W
B
Y/Gr
Br
B
Y/Gr
Br
B
Y/Gr
B
Or
Br
B
Br
Y/Gr
B
X101
18
17
20
19
21
24
4
X10
12
X20
16
25
2 1
1
NTC 5
9
2 1
1
NTC 2
10
2 1
1
NTC 1
11
123
1
21234123456
X7
X4
X6
X5
Bus A
Bus - Ground
Bus B
0-10 Volt - Ground
0-10 Volt - Input
Cascade sensor - Ground
Cascade sensor - Input
NTC 3
NTC 4
1
2
22
23
26
X18
V
W
B
W
B
B
9 10 11 12 13 14 15 16
16 15 14 13 12 11 10 9
X100
7
Y/Gr
Y/Gr
B
W
B
W
B
V
B
Br
Y/Gr
B
Br
B
Br
Y/Gr
P4 P3
FL
27
5AT Fuse
5AT Fuse
5AT Fuse
CH & DHW Settings
Boiler Settings
Boiler Settings
Prestige Model Solo/Excel. 3way valve
Lockout Temp. 105°C
Modbus Address 1
Pump settings
Ignition Level 3100rpm
Pump Settings
Current Pump Cong Solo/Excellence 1
Preset Pump Cong
Flexible Pump Cong
ACCESSING THE PRESET CONFIGURATION PAGE FOR THE SOLO/EXCEL.
(3-WAY VALVE)
To access the preset conguration page, follow the selections shown on the screens below (Installer menu)
Pump Conguration 1
Flex 4
ERR
Flex 6
P4
Flex 3
P3
Flex 2
DHW
Flex 1
CH
Flex 5
Flame
Error CH2 CH1 CH1/CH2/
DHW
Flame
In the following hydraulic diagrams, this representation is used :
Warm water
Cold water
Preset Pump Cong
Solo / Excellence 1
Solo / Excellence 2
Solo / Excellence 3
Solo / Excellence 4
Do not forget to select the correct
boiler in the Boiler Settings, Prestige
Model.
59

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für ACV Prestige Solo wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info