Thank you for purchasing this high-quality product made by ADE. You have acquired a
set of scales that meet the highest technical standards and are of proven quality.
Please read these operating instructions carefully before using the product for the first
time and keep them in a safe place where you can find them whenever you need the
information contained in the instructions.
1. How does the body analyser work?
Through this new revolutionary scale, you will be able to get information about your body
composition with reference to your weight, body fat %, body water % and muscle mass
%. First, you have to enter once your personal data like body height, age, gender under
your selected personal memory location. Afterwards a measurement is as simple as on a
normal bathroom scale. You have only to push your personal memory location, step on
the scale and within a few seconds, your measured values will be indicated. The analysis
based on the measurement of the body’ s electrical resistance. A low, safe electrical
signal passes freely through fluids contained in lean tissue, such as muscle and blood,
but meets resistance passing through fat tissue. The body analyser accurately measures
the resistance and with reference to your personal data use it to calculate elements of
body composition.
2. How to use
If possible, the measurement should be done undressed but always barefoot.
By nature, a body is subject of fluctuations (for example loss of water after taking
exercise or after a sauna visit, after a meal, etc.). To enable comparable readings it is
important to take the measurements as possible always under the same conditions.
In order to ensure that the results of analysis are accurate and consistent, please keep
the measurement conditions constant always at the same daytime. In the morning,
directly after you’ ve woken up, your body will be dehydrated and also the majority of fluid
will be stored in the central trunk area. This means that the resistance is relatively high
because of the poor conductivity in the body. By intensify moving during the day
progresses the fluid becomes more evenly distributed through the limbs and increasing
the accuracy of the readings. To get a realistic result it is important to take your readings
at the same time and under the same conditions every day. The easiest way to stick the
rule, measure always in the morning, 15 minutes after you’ ve got up, either before or
after you’ ve gone to the bathroom.
In spite of a very low electrical signal, this body ana lyzer is not suitable for persons
with hea rt pacemaker or other electronic medical implants! There is no risk for
persons with none electronic implant for instance a titanium plate in the knee. However,
metal conducts the electric current extremely well and therefore the scale implicates the
body fat value beautified” means the actual body fat value is higher as indicated.
However, tendencies may be determined as well.
7. Error Messages
FFFF“ = Overload display The 150 kg maximum capacity of the scales
has been exceeded. Immediately remove the load from the
scales; otherwise, the load cell could be damaged.
Lo“ = Indication that the battery is flat Please replace the batteries
with four 1.5 V type AA.
8. Technical Data
Capacity x graduation: max. 150 kg x 100 g
Display resolution: body fat: 0.1%
Display resolution: body water: 0.1%
Display resolution: muscle mass: 0.1%
Personal memory loc.: 12 positions
Age: 9 – 99 years
Body height: 90 250 cm
Dimensions: 330 mm x 330 mm x 36 mm
Batteries: 4 x 1.5V AA (included)
Subject to technical changes due to further-development of the product.
5. Guarantee
ADE guarantees to rectify any defects due to material or manufacturing defects by means
of repair or replacement free of charge for a period of three years. At the time of purchase,
please get the retailer to fill in and stamp the guarantee card. In the case of guarantee
claims, please return the scales to your retailer including the guarantee card and stating
the reasons for the claim.
CE conformity
This device is interference-suppressed in accordance with
the applicable EU directive 2004/108/EC
Note: Extreme electromagnetic influences, e.g. when operating radio communication
equipment is being operated next to the scales, can affect the displayed value. When the
interference is over, you can use the product for its intended purpose again; it may be
necessary to switch it on again.
7
2
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ade BA 719 Tanja wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info