Thank you for purchasing this high-quality product made by ADE Germany. You have
acquired a set of scales that meet highest technical standards and are of proven quality.
Please read these operating instructions carefully before using the first time and keep
them in a safe place where you can find them whenever you need the information
contained in the instructions.
1. Putting into Service
Activate the batteries / Replace batteries:
To replace the battery open the battery compartment. Move the battery at the recess
downwards and the battery will be easy to take out. Make sure that you do not bend the
contact. Insert the new battery (1 x CR2032) and close the battery compartment.
Safety guidelines:
Ensure that no objects fall onto the scales; otherwise, the scales
may be damaged.
Only use a damp cloth to clean the scales. Never use solvents
or abrasive cleaners. Do not put the scales under water. You
must clean all the plastic parts of the scales immediately after
they come into contact with grease, spices, vinegar or any other
spiced or coloured foods. Avoid any contact with citric acid.
To remove the bowl (e.g. for cleaning) push the pushbutton below the handle and
remove the bowl.
2. Operation
Switching on the scales:
To switch-on the scales push the ON/OFF/TARA-button. At first, the LCD indicate for a
few seconds the characters 8888” and after the scales have stabilised, they display
“0 g“. The scales are now ready to weigh.
Units of weight / Liquid mode:
A longer push of the Hold/Unit-button in weighing mode allows you to change the unit of
weight (g = gram / lb:oz = pound ounce / ml = millilitre / fl.oz = fluid ounce). If you have
chosen the mode ml (millilitres), you can push the liquid-button (drop symbol) to weigh
water, milk, or oil. Please ensure that the scales are set to the appropriate units of weight
for you.
Weighing:
Place the scales on a firm, level base and switch-on the scales. After the scales have
stabilised, they display “0 g“. Put the item to be weighed into the bowl. After stabilization
of the weight indication, the weight of the placed item is readable in the display.
Hold-func tion:
By pushing the Hold/Unit-button, while the weight indication is stable you can hold the
reading. When Hold-function is active, the symbol “H” appears in the display. To
deactivate the Hold-function push the Hold/Unit-button again.
Tare-function:
Pushing the ON/OFF/TARA-button allows you to set the scales to “0 g”. Put the weighing
charge into the bowl. Upon the weight is indicated and stable push the ON/OFF/TARA-
button and in this way set the scales back to “0 g”. You can repeat this procedure as
often as you like until the total capacity of the scales (5 kg) has been reached. After you
remove the item(s) to be weighed, the total weight is displayed as a minus value. Please
take care not to move the weighing platform during the tare procedure.
Automatic switch-off the scale:
If the indicated weight does not change within approx. 90 seconds, the scales switches-
off automatically. You can switch-off the scales manually after you have finished using
them by pushing the ON/OFF/TARA-button for approximately two seconds.
3. Error Messages
“LO“ = Indication that the battery is flat - Please replace the battery
with the intended type (one type CR2032).
“Err“ = Overload display - The 5 kg maximum capacity of the scales
has been exceeded. Immediately remove the load from the
scales; otherwise, the load cell could be damaged.
4. Technical Data
Capacity x graduation: max. 5 kg x 1 g
Max. volume bowl: 2.5 litre
Dimensions: 290 mm x 220 mm x 150 mm
Battery: 1 x CR2032 (included)
Subject to technical changes due to further-development of the product.
5. Guarantee
ADE guarantees to rectify any defects due to material or manufacturing defects by means
of repair or replacement free of charge for a period of three years. When making a
guarantee claim, please return the scales together with the sales slip to your retailer and
stating the reasons for the claim.
2
3
Open the
lid of the battery compartment on the bottom
of the
scales and remove the battery safety strip. Please observe the
correct polarity of the battery (+/-).
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ade KE 1100 Annabelle wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info