Thank you for purchasing this high-quality product made by ADE. You have acquired a
set of scales that meet the highest technical standards and are of proven quality.
Please read these operating instructions carefully before using the product for the first
time and keep them in a safe place where you can find them whenever you need the
information contained in the instructions.
1. Putting into Service
Inserting the batteries:
Open the lid of the battery compartment on the bottom of the scales and insert the three
supplied 1.5 V AAA batteries. Please observe the correct polarity of the batteries (+/-).
Safety information:
Ensure that no objects fall onto the scales; otherwise, the scales
may be damaged.
Only use a damp cloth to clean the scales. Never use solvents
or abrasive cleaners. Do not put the scales under water. You
must clean all the plastic parts of the scales immediately after
they come into contact with grease, spices, vinegar or any other
strongly spiced or coloured foods. Avoid any contact with citric
acid.
2. Operation
Switching on the scales:
Place the scales on a firm, level base. The scales are equipped with highly sensitive
touch buttons. To switch-on the scales touch the /Tare-button. After the scales have
stabilised, they display "0 g" / “0.0 oz” / “0 mlor “0.0 fl.oz“, depending on the setting.
The scales are now ready to weigh.
Note: Display the scales a value after power-on, touch the /Tare-button to set the
scales back to “0 g”.
Units of weight:
Turning the knob (in weighing mode) allows you to change country-specific units of
weight (g = grams / oz = ounces / ml = millilitres / fl.oz = fluid ounces). Please ensure
that the scales are set to the appropriate units of weight for you.
Tare func tion:
Touching the /Tare-button allows you to set the scales to "0 g". Place a bowl, for
example, on the platform of the scales, touch the /Tare-button and in this way set the
scales back to "0 g" (is the weight to be tared heavier than 600 g appears bottom left of
the display the TARE-icon). You can repeat this procedure as often as you like until the
total capacity of the scales (5 kg) has been reached. After you remove the item(s) to be
weighed, the total weight is displayed as a minus value.
Automatic- / manua l switch-off the scale:
If the indicated weight does not change within approx. 10 seconds, the backlight of the
scale switches-off automatically. If the indicated weight does not change within approx.
50 seconds, the scales will automatically switch-off. You can switch-off the scales
manually after you have finished using them by touching the /Tare-button for
approximately two seconds.
3. Timer
Set-up timer:
Push the knob to switch-on the scales and to enter the timer mode. The display indicates
"Timer 00:00”. When you used the timer-function once before the previous time-input
appears. Pushing the knob for approx. 2 seconds allows you to set the time indicating
back to 00:00”. Now you can turn the knob to set the desired time. By turning up
(clockwise) the seconds; by turning down (counter clockwise) the minutes. After entering
the desired time, push again the knob to confirm the input. The timer runs and after expiry
of time a loud peep-tone sounds for about 60 seconds. Stop the beep by touching the
/Tare-button or push the knob. During expiration, the timer-function can anytime be
stopped and/or required to operate by pushing the knob.
Note: If, within about 10 seconds before the start of the timer, no further action takes
place, the backlight of the scales switches-off automatically and after approx. 20 seconds,
the scales will automatically switch-off.
Switch between timer- and weighing mode:
If the scales are in weighing mode, push the knob to enter the timer mode. The weighing
function is closed.
If the scales are in timer mode, touch the /Tare-button to enter the weighing mode. If
the timer was previously activated, the timer function runs unto the expiry of time,
except the function has been stopped by touching the /Tare-button for approx. 2
seconds and the scales is thereby off.
4. Error Messages
“Lo“ = Indication that the battery is flat Please replace the batteries with
three 1.5 V type AAA.
“EEEE” = Overload displayThe 5 kg maximum capacity of the scales has been
exceeded. Immediately remove the load from the scales; otherwise, the
load cell could be damaged.
2
3
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ade KE 1138 Mara wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info