641989
4
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
Thank you for deciding to purchase this high-quality product from the ADE Company.
You have purchased a set of scales of the highest technical standard and proven quality.
Please read through this operating manual carefully before starting-up the scales for the
first time, and keep it in a safe place so that this information is available to you when you
need it.
1. Start-up
Inserting the batteries:
Open the battery compartment cover at the back of the scales and insert the provided
batteries (2 x 1.5V AAA). Please be mindful of the correct polarity of the batteries (+/-).
Safety information:
Please take care not to let any objects fall onto the scales,
otherwise the scales could be damaged.
Only clean the scales with a damp cloth. Do not use any solvents or
abrasive cleaning products. Do not immerse in water. All plastic
parts of the scales should be cleaned immediately after contact
with fat, spices, vinegar and other strongly seasoned and coloured
foodstuffs. Avoid contact with citric acid.
2. Operation
Activating the scales:
Place the scales on an even and firm surface. The scales make use of highly sensitive
sensor buttons (Sensor Touch). To activate the scales touch the SS | -button on the
bottom right of the display. The figures 8888” will first appear on the display. After the
scales have stabilised, 0 g” or “0: 00 lboz” will appear depending on the settings. The
scales are now ready for weighing.
Please note: If, after activating the scales, a weight-value is displayed, touch the SEC |
TARE -button to set the scales to zero.
Chan ging the unit of weight:
By touching the MIN | G/LB -button you can change the country-specific unit of weight
(g = gram / lboz = pound ounce). Please make sure that the scales are set to the unit of
weight relevant to you.
Zeroing-(Tare)-func tion:
By touching the SEC | TARE -button you can set the scales to “0 g”. Activate the scales
and place, for example, a bowl on the weighing platform, press the SEC | TARE -button
and thus set the scales to “0 g” again. This process can be repeated as often as you like
until the total capacity of the scales (5 kg) is reached. After removing the weighed item the
total weight will be displayed as a negative value.
Automatic / manua l deactivation of the scales:
If the displayed weight does not change within approx. 30 seconds, the backlight
deactivates and after approx. 3 minutes the scales automatically deactivate. By touching
the SS | -button for approx. 2 seconds you can also manually deactivate the scales
after using them, in order to conserve battery power.
3. Timer
Setting the timer:
Touch the SS | -button in order to activate the scales. Touch the SS | -button a
second time in order to get to timer mode. The letters “M” (minutes) und “S” (seconds) as
well as the indicator 00:00” (time setting) will appear on the display. If you have already
used the timer function, the previously specified time will appear. By simultaneously
pressing the MIN | G/LB and SEC | TARE buttons you can reset the time display to
00:00”. Now by touching the MIN | G/LB -button you can set the desired minutes, and
by touching the SEC | TARE -button you can set the desired seconds. To set the values
more quickly, hold your finger down on the respective button. After entering the desired
time, touch the SS | -button again to confirm. The timer will count down and after
reaching the end a loud beep will sound for approx. 60 seconds. Stop the beeping by
touching a button. During countdown the timer function can, at any time, be stopped
and/or resumed by touching the SS | -button.
Stopwatch func tion:
Touch the SS | -button in order to activate the scales. Touch the SS | -button a
second time in order to get to timer mode. Touch the SS | -button a third time in order
to activate the stopwatch function. While it is running the stopwatch function can, at any
time, be stopped and/or resumed by touching the SS | -button. By simultaneously
touching the MIN | G/LB and SEC | TARE buttons you can reset the time indicator to
00:00”.
Please note: If, within 30 seconds after starting the timer or the stopwatch, no further
activity takes place, the backlight will deactivate but the timer or stopwatch will remain
active.
4. Error messages
Lo = Display battery empty – please replace the batteries with the battery type
intended for your scales (2 x 1.5V AAA).
O-Ld = Overload indicator max. capacity of scales 5kg has been exceeded.
Remove the load from the scales immediately, otherwise the load cell
could be damaged.
5. Technical Data
Weight-bearing capacity x division: Max. 5 kg x 1 g
Dimensions: 220 mm x 165 mm 16.5 mm
Batteries: 2 x 1.5V AAA
We reserve the right to make technical modifications in the course of further development.
3
2
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ade KE 1424 Muriel wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info