694305
34
Zoom out
Zoom in
Vorherige Seite
1/97
Nächste Seite
34
If the wood burning stove is to be placed close to flammable material such as a wooden floor or carpet, it
must be placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the
wood burning stove and 15 cm on each side measured from the opening of the combustion chamber.
2.2 Pipe connection
Aduro 17 / 17 Lux leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on
the back, “brake” the two cover plates on top of the back of the stove. Exchange the exhaust connector (from
the top outlet) with the cover plate from the rear outlet. Mount the cover plate from the rear outlet to the top
outlet. The top outlet is finished with the plate that lies in the ashpan. A flue pipe with an internal diameter of
150 mm should be used for Aduro stoves.
Please ensure that building regulations are complied with, including CE marking of the exhaust connector.
Additionally, distance requirements to flammable material for the exhaust connector must be respected.
2.3 Connection to a brick chimney
If the stove is being connected to a brick chimney, the rear outlet or a curved flue pipe via the top outlet
should be used. After measuring, a hole is made in the chimney in which the pipe sleeve is placed and stove
mortar is used to seal it in place. The stove is placed in position and the flue pipe is put in place. A thin
gasket is placed between the flue pipe and the pipe sleeve to seal the joints. The flue pipe should protrude 5-
10 cm into the pipe sleeve, but must not block the opening in the chimney (see the illustration below):
The stove can be connected to a chimney to which other heat sources are connected.
2.4 Supply of combustion air
All wood burning stoves need constant supply of air to ensure a clean and efficient combustion. This is often
a problem in modern energy-efficient houses that are very tight. Therefore, the Aduro 17 / 17 Lux is equipped
with external supply of combustion air, where the air to the combustion is supplied from the outside and directly
into the wood burning stove. Air from the outside can be provided through a channel, which is connected to
the connecting pipe under the combustion chamber. The amount of air needed for combustion is 25m3/h.
The wood burning stove must be installed on a floor with the adequate load-
bearing capacity. If the existing construction does not meet this requirement,
appropriate adaptation measures must be taken (e.g. a load-distributing plate).
X
34

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aduro 17 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info