3. Lighting the stove
Important safety information
The wood burning stove will become warm during use and therefore it should be treated with all
necessary caution.
Never keep easily combustible fluids such as petrol in the vicinity of the wood burning stove.
Never use easily combustible fluids to light the fire in the wood burning stove.
Never empty the ashpan when the wood burning stove is warm. Embers may still be found in the
ashpan for up to 24 hours after the fire has gone out. Please wait to empty the ashpan until you
are sure that there are no embers in the ash.
The door should be kept closed while the wood burning stove is in use. While lighting the fire, the
door can stand ajar for the first few minutes.
In the event of a chimney fire: Close all the dampers on the wood burning stove and call the fire-
fighting service.
3.1 Damper
The stove is equipped with a damper under the door, which regulates the combustion air: primary,
secondary, and tertiary air supply. The primary air is used at the beginning to get the fire going, the
secondary air keeps the fire burning evenly, and the tertiary air ensures that flue gasses are burned. You
must always add secondary and tertiary air, while firing the stove.
The damper allows you to adjust the stove according to the chimney draft and the heat output you require.
The longer the damper is pulled out, the more air is added and the more powerful the combustion. The
illustration below shows the stove seen from the front with the dampers indicated. Use edge of door to read
position of inlet air:
3.1.1 Secondary air supply
In normal circumstances, the wood burning stove should be working with this damper open between 60 %
and 100 %. You should never close the air intake so far that the flames are extinguished. There should
always be visible flames in order to achieve clean and efficient combustion. A too low supply of air can lead
to bad combustion, high emissions and a bad efficiency. The air-wash system that minimizes soot collecting
on the glass panes is also adjusted by this damper.
1: Fully open primary, secondary, and tertiary air inlet.
This position can be maintained with the Aduro key,
which must be placed in the two holes.
2: Closed primary air inlet, fully open secondary and
tertiary air inlet.
3: Closed primary air inlet, half way closed secondary air
inlet and fully open tertiary air inlet.
4: Closed primary and secondary air inlet, fully open
tertiary air inlet.
5: Regulator pushed all the way in. All air inlet closed.
37

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

aduro-9.5-lux

Suche zurücksetzen

  • Wo sind die Zugregler
    Ofen gerade installiert brennt aber nur bei offener Tùr Eingereicht am 16-9-2022 08:28

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aduro 9.5 Lux wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info