1.
Drain the water collection tank
completely and leave the bottom
drain cap and rubber plug long time
enough to allow any residual water to
drain out. Once the tank is completely
drained and no more water ows out,
reinstall the rubber plug and cap.
1.
Make sure the lter and drain cap are
in place.
2.
Check the cord to make sure it is in
good condition, without cracks or
damage.
3.
Place new batteries in the remote
control.
4.
Install the air conditioner as described
in the Installation Instructions.
2.
Wash the lter using liquid
dishwashing detergent and warm
water under 40°C. Rinse lter
thoroughly. Gently shake excess
water from the lter. Be sure lter is
thoroughly dry before replacing. Or,
instead of washing you may vacuum
the lter clean.
3.
Replace the lter after the lter is dry.
Be sure lter is thoroughly dry
before replacing.
If the air conditioner will not be used for
an extended period of time:
Before using the air conditioner again:
8.3 Winter Storage
9.
TROUBLE SHOOTING
Before calling for service, review this
list. It may save you time and expense.
This list includes common occurrences
that are not the result of defective
workmanship or materials in this
appliance.
Air conditioner will not operate.
Air from unit does not feel cold enough.
Air conditioner cooling, but room is
too warm - NO ice forming on cooling
coil behind decorative front.
Wall plug disconnected. Push plug
rmly into wall outlet.
House fuse blown or circuit breaker
tripped. Replace fuse with time delay
type or reset circuit breaker.
Control is OFF. Turn Control ON and
set to desired setting.
Fault code P1 appears in the display
window. Drain water as described in
7.3 Drainage Section.
Room Temperature lower than the set
temperature (Cool Mode) or Room
Temperature higher than the set
temperature (Heat Mode). Reset the
temperature.
Room temperature below 16°C.
Cooling may not occur until room
temperature rises above 16°C.
Reset to a lower temperature.
Compressor shut-o by changing
modes. Wait approximately 4 minutes
and listen for compressor to restart
when set in the COOL mode.
Outdoor temperature below 16°C.
To defrost the coil, set Fan mode.
Air lter may be dirty. Clean lter.
Refer to 8. Care and Cleaning section.
To defrost, set to Fan mode.
Temperature is set too low for nighttime
cooling. To defrost the coil, set to Fan
mode. Then, set temperature to a higher
setting.
Exhaust duct not connected or blocked.
See 5.1 Exhausting hot air Section.
2.
Remove and clean the lter, allow it
to dry completely, then reinstall it.
3.
Remove the batteries from the
remote control.
4.
Store the air conditioner in a cool,
dry location, away from direct
sunlight, extreme temperature,
excessive dust, and well ventilated.
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für AEG AXP35U538CW wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info