ENGLISH
achieved by breaking the vacuum in the
system with OFN and continuing to ll
until the working pressure is achieved,
then venting to atmosphere, and nally
pulling down to a vacuum. This process
shall be repeated until no refrigerant is
within the system. When the nal OFN
charge is used, the system shall be
vented down to atmospheric pressure to
enable work to take place. This operation
is absolutely vital if brazing operations on
the pipework are to take place.
Ensure that the outlet for the vacuum
pump is not close to any ignition sources
and there is ventilation available.
In addition to conventional charging
procedures, the following requirements
shall be followed.
Charging procedures
Ensure that contamination of dierent
refrigerants does not occur when
using charging equipment. Hoses or
lines shall be as short as possible to
minimise the amount of refrigerant
contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is
earthed prior to charging the system
with refrigerant.
Label the system when charging is
complete (if not already).
Extreme care shall be taken not to
overll the refrigeration system.
Prior to recharging the system it shall be
pressure tested with OFN. The system
shall be leak tested on completion of
charging but prior to commissioning.
A follow up leak test shall be carried
out prior to leaving the site.
Before carrying out this procedure, it is
essential that the technician is completely
familiar with the equipment and all its
detail. It is recommended good practice
that all refrigerants are recovered safely.
Prior to the task being carried out, an oil
and refrigerant sample shall be taken in
case analysis is required prior to re-use
of reclaimed refrigerant. It is essential
that electrical power is available before
the task is commenced.
Decommissioning
1.
Become familiar with the equipment
and its operation.
2.
Isolate system electrically.
3.
Before attempting the procedure
ensure that:
Mechanical handling equipment is
available, if required, for handling
refrigerant cylinders;
All personal protective equipment is
available and being used correctly;
The recovery process is supervised
at all times by a competent person;
Recovery equipment and cylinders
conform to the appropriate
standards.
4.
Pump down refrigerant system,
if possible.
5.
If a vacuum is not possible, make
a manifold so that refrigerant can
be removed from various parts of
the system.
6.
Make sure that cylinder is situated
on the scales before recovery takes
place.
7.
Start the recovery machine and
operate in accordance with
manufacturer's instructions.
8.
Do not overll cylinders. (No more
than 80% volume liquid charge).
9.
Do not exceed the maximum working
pressure of the cylinder, even
temporarily.
10.
When the cylinders have been lled
correctly and the process completed,
make sure that the cylinders and
the equipment are removed from
site promptly and all isolation valves
on the equipment are closed o.
11.
Recovered refrigerant shall not be
charged into another refrigeration
system unless it has been cleaned
and checked.
Equipment shall be labelled stating that it
has been de-commissioned and emptied
of refrigerant. The label shall be dated
and signed. Ensure that there are labels
on the equipment stating the equipment
contains ammable refrigerant.
Labelling
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für AEG PX71-265WT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info