Connection
Relieve the strain on the electrical connecting leads as required and connect according to the
electrical circuit diagram in the device (on the inside of the right side wall) or the connection
diagram opposite.
If the angle plate in the switching area for holding the mains terminals is poorly accessible due to
too small a spacing, it can be swung forward during connection work after loosening the screw
(not removing) in the rear wall.
Voltage (230 V) must be applied to the terminal ”L” of the terminal strip X2 during the charging
time.
If no separate power supply is available for this, the terminal ”L1” can be bridged with ”L”. In this
case the terminal ”N” of the terminal strip X2 must always be bridged terminal ”N” of terminal
strip X1.
Please make sure that the protective earth is connected properly!
The cable for connecting a DC control signal must be insulated with a hose inside the unit from the
strain relief to the connecting terminal before connecting.
Control without heater contactor
If no heater contactor is to be installed (partly energy supply company requirement) the thermal
relay installed in the storage heater at the factory can be used.
For this, either the energy supply company signals ”LF” and ”N” or the signals ”SH” and ”N” of the
respective charging control must be connected directly to the terminals ”L-SH” and ”N” of the
storage heater. The notes marked * in the connection diagram must be observed.
L-
L
SH
Brücken (L) - (L-SH) und (N) - (N)
bei Ansteuerung Heizungsschütz
entfernen
ohne
NNN NN
LE
X2
à
à
à
For the Fitter
The heating elements in the unit are not switched on until the energy supply company has released
the LF and the electronic charging control unit starts charging.
A bridged must be inserted between ”N” and ”A2/Z2” for operation with ”single-wire control”** !
Observe the unit rating plate!
2.5.3 Unit Ready for Operation
Cleaning the unit (fig. 13)
The open unit must be cleaned after installation and insertion of the storage blocks.
Close the unit (fig. 14 and 15)
Place the inside front panel including heat insulation with the side edging on the supports at the
bottom, press the unit on top and screw together.
Hang in the right side wall at the bottom, tilt up, hang in at top and fix with screw; (reverse
order see 2.5.1 – disassembly right side wall fig. 6)
Hang in front wall at top, swing to the heater at the bottom and fix with 2 screws (always use
the two inside threaded holes) (fig. 14);
Screw on the air outlet grille, screwing the screws hand tight and then back about 1 turn
(fig. 15);
Place the air inlet grille at an angle on the lugs in the heater base, swing round at the top and
snap in behind the air outlet grille (fig. 15).
Remove the bridges (L) - (L-SH) and
(N) - (N) for control without
contactor
03 GB WSP_1510S.p65 27.01.2004, 16:3231
29

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für AEG WSP 1510 S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info