For the Fitter
2.3.3 Running in the supply cables
When integrating the heater into a built-in kitchen, measure off enough length of low-voltage,
high-voltage and charge control supply cable to allow the heater to be electrically connected
before integrating it below the working top. It is then possible to pull the heater out of its recess
at a later date, for instance for repair work, without having to disconnect the supply cables.
Before sliding the heater into its recess, bring in the supply cables from the rear of the heater
through the cable feed on the lower left hand side of the rear panel and through the cable ties on
the inner left side of the heater into the connecting compartment. Run the cables through the
strain relief below the switching panel and clamp them tight. Pull the cable ties on the left side of
the heater tight.
Caution: Make sure that the connecting cables run flush to the heater's left side and
cannot touch the fan compartment. Hot surfaces!
When sliding the heater into its recess, make sure that the connecting cables are
not unduly bent or pinched. The connecting cables must be run so that they have
free movement behind the plinth recess.
2.3.4 Electrical connection
The storage heater appliance is connected to a load current (OFF-PEAK tariff) and control cables
for the room thermostat and for the charge control (A1/Z1; A2/Z2). The cables A1/Z1 and A2/Z2
are at line-voltage 230V~ and may thus be run together with a L/N/PE cable for the room
thermostat. The heater is suitable for direct connection without a spur, or with a wall socket.
According to regulations every branch circuit must be individually protected, for instance by
circuit breakers for all phases. These circuit breakers must have contact openings of at least
3 mm.
Each heater must be connected to a separate current carrying cable from the electrical
junction box. Running the load current cable from heater to heater is not allowed.
According to the Utilities' Technical Connection Regulations, a single-phase connection is
only allowed for heaters up to 2 kW rating. To do this, bridge the terminals L1-L2-L3.
When connecting to a charge control with a so-called "single-wire control", bridge the
terminals “A2/Z2” and “N”.
Make sure the earth wire is correctly and firmly attached.
If the heater is to be used with a connecting rating of only 2 kW, do not connect the upper
heating element.
The AEG Kitchen Heater is factory-equipped with an electronic charge and discharge control.
The charger can be connected to an automatic charging device with an 80 % duty cycle
(square-wave, digital control signal), e.g. µC2100, µC3000 The discharge side includes the room
temperature sensor and the set point adjuster. An external room thermostat is not necessary.
Caution: Terminals L and N must be connected to continuous voltage (ON-PEAK cable). If
an external room thermostat is fitted, this must not switch terminal L to a
voltage-free state.
If a night-time set-back is required, bridge terminals TA-TA to a time-clock by means of a floating
contact. The night-time set-back is fixed at 3K.
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für AEG WSP 300 H wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info