A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
FO2 50% Default -
> When the Default is set OFF, FO2 values will remain set at their last settings saved until 24 hours elapse without conducting
a dive.
> When the Default is set ON and FO2 is set for Nitrox, 10 minutes on the surface after that dive the FO2 will be displayed
as 50 and further dives will be calculated based on 50% O2 for oxygen calculations and 21% O2 for Nitrogen calculations
(79% Nitrogen), unless FO2 is set before the dive.
> FO2 will continue to reset to the Default after repetitive dives until 24 hours elapse with no dive, or the Default is set OFF.
SET F (FO2) MENU, information includes (Fig. 22):
> Graphics SEt and MENU,
with the following graphic selections with their last Set Points saved.
> GAS1 AIR
Set Points of AIR, 21 to 100%, increments of 1%
.
> GAS2 32%
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> GAS3 80%
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> GAS4 OFF
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> DEFAULT ON
Set Points of OFF, ON
.
When Gas 2 is OFF, Gas 3 & 4 remain OFF, and when Gas 3 is OFF Gas 4 will remain OFF. This blocks access to the Gas
Switch screens for gasses not selected for use.
During the time that numeric FO2 values (21 to 100) are flashing, the MOD (Max Operating Depth) allowed for the PO2
alarm set will be displayed in place of the graphic SEt, and the PO2 alarm value set will be displayed in place of the
graphic MENU.
• S (< 2 sec) - to access Set F Menu while the selection Arrow icon ( > ) is next to Set F on the NORM Menu.
• A (< 2 sec) - to step down (forward) through selections.
• M (< 2 sec) - to step up (back) through selections.
• S (< 2 sec) - to access selection indicated by Arrow icon ( > ).
This causes the FO2 setting to flash allowing it to be set.
• S (2 sec) - to step back from Set F Menu to SET Menu.
SET FO2 & PO2 ALARMS:
A (press/hold), while the FO2 digits are flashing (Fig. 23A) - to scroll upward through the Set Points from Air to 21 through
100 in 1% increments, at a rate of 8 per second.
The scroll will stop when the button is released, or momentarily at 32, then 50, then 80 (%).
A (< 2 sec) - to step upward through FO2 Set Points one at a time.
M (< 2 sec) - to step back through FO2 Set Points one at a time.
S (< 2 sec) - save the FO2 setting, and flash the PO2 digits if Nitrox (Fig. 23B), or revert to SURF MAIN if Air.
A (< 2 sec) - to step upward through PO2 Alarm Set Points from 1.00 to 1.60 (ATA) in .05 increments.
M (< 2 sec) - to step back through PO2 Set Points.
S (< 2 sec) - to save the PO2 setting and access Set Gas 2.
S (2 sec) - to revert to Set F Menu displaying the settings.
M (2 sec) or if no button is pressed during a 2 minute period - to revert to SURF MAIN.
Once any Gas is set for Nitrox, any other Gas set for Air will automatically be set to 21%.
SET FO2 50% DEFAULT, information includes (Fig. 23C):
> Graphics DEFAULT and 50.
> Set Point graphic OFF (or ON), flashing.
> Nx icon.
• A or M (< 2 sec) - to toggle between OFF and ON.
• S (< 2 sec) - to save the setting and revert to Set F.
SET A (ALARMS) MENU, information includes (Fig. 24A/B):
> Graphics SEt A and MENU,
with the following graphic selections with their last Set Points saved.
> AUD ON
Set Points of OFF, ON >> Audible.
> DEPTH 140 FT
Set Points of OFF, 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M).
> EDT 60 MIN
Set Points of OFF, 10 to 180 MIN, increments of 5 MIN >> Elapsed Dive Time.
> TLBG* 4 BAR
Set Points of 1 to 4 BAR, increments of 1 BAR >> Tissue Loading Bar Graph.
> DTR* 5 MIN
Set Points of OFF, 1 to 20 MIN, increments of 1 MIN >> Dive Time Remaining.
> TURN 1400 PSI
Set Points of OFF, 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR).
> END 500 PSI
Set Points of 300 to 1500 PSI (or 20 to 105 BAR), increments of 100 PSI (5 BAR).
*These items apply to NORM only.
A (< 2 sec) to toggle or increase Set Point.
A (hold) to increase Set Point at a rate of 8 per second.
M (< 2 sec) to decrease Set Point.
S (< 2 sec) to save the setting and revert to the Set A Menu.
• S (2 sec) - to step back from Set A Menu to SET Menu.
Fig. 22 - SET F MENU
(stepping through)
Fig. 23A - SET FO2
(changing the setting)
Fig. 23B - SET PO2 ALARM
(after FO2 setting is saved)
Fig. 23C - SET FO2 50%
DEFAULT
Fig. 24A - SET A MENU
(stepping through)
Fig. 24B - SET END ALARM
(sample of changing a setting)
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aeris A300 AI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info