A300 CS OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-7287-r04 (8/21/14)
TRANSMITTER BATTERY REPLACEMENT
Battery Removal
Locate the Battery Cover on the end of the housing:
Apply a coin to the recessed slot of the Cover and turn it counter clockwise out of the housing (Fig. 101).
Remove the Battery and discard it according to local regulations governing disposal of Lithium batteries.
Battery Installation
Lightly lubricate the new Battery Cover O-ring with silicone grease and install it onto the Battery Cover. DO NOT roll the
O-ring over the Threads, instead stretch it slightly to work it down over the slotted end of the Cover into the groove at the base
of the threads (Fig. 102).
The O-ring must be a genuine AERIS part that can be purchased from an Authorized AERIS Dealer.
Use of any other O-ring will void the warranty.
• Insert a new CR2 Lithium 3 Volt Battery (Duracell or equivalent) positive (+) side first into the Battery compartment with the
negative end facing out (Fig. 103).
• Ensure that the Battery is properly installed and the Cover O-ring is evenly seated around the Cover.
• Carefully place the Cover (with spring) into the housing and turn clockwise slowly by hand to ensure proper threading.
• Apply a coin and tighten the Cover by turning it clockwise until secure (Fig. 104). The outer surface of the Cover should be
flush with the outer surface of the housing.
TRANSMITTER INSTALLATION ON A REGULATOR
• Remove the existing pressure gauge and high pressure hose, or the high pressure port plug from the port marked HP using
the proper size hex key.
• Lightly lubricate the o-ring and threads of the Transmitter fitting with a halocarbon based lubricant such as Christo-Lube
MCG111.
• Thread the Transmitter clockwise by hand into the regulator's HP port (Fig. 105) and tighten until secure with an appropriate
sized open end wrench.
• Attach the regulator First Stage to a full scuba tank and pressurize by slowly opening the tank valve, listening for any
indication of air leaking around the fitting.
• If air leakage is present, DO NOT use, take the complete regulator assembly to an Authorized AERIS Dealer for inspection
and service.
TRANSMITTER COMPATIBILITY WITH NITROX
When packaged and shipped from the factory, AERIS Transmitters are rated for use with compressed Air and/or nitrogen-oxygen
(Nitrox) breathing gas mixtures containing up to 99% O2 by volume and with 100% O2.
Fig. 103 - ORIENTATION
Battery
(+) ( - )
Fig. 101 - COVER
REMOVAL
Fig. 102 - INSTALLING
COVER O-RING
Fig. 104 - TRANSMITTER
COVER INSTALLED
Fig. 105 - TRANSMITTER ON
FIRST STAGE
WARNINGS
Decompression diving, or diving deeper than 130 FT (39 M), will greatly increase your risk of decompression sickness.
Decompression diving is inherently hazardous and greatly increases your risk of decompression sickness, even when performed
according to the dive computer's calculations.
Using an A300 CS is no guarantee of avoiding decompression sickness.
The A300 CS enters Violation Mode when a situation exceeds its capacity to predict an ascent procedure. These dives represent
gross excursions into decompression that are beyond the boundaries and spirit of the A300 CS's design. If you are following
these dive profiles, AERIS advises that you should not use an A300 CS.
If you exceed certain limits, the A300 CS will not be able to help you get safely back to the surface. These situations exceed
tested limits and can result in loss of some functions for 24 hours after the dive in which a violation occurred.
55

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aeris A300 CS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info