618066
6
Zoom out
Zoom in
Vorherige Seite
1/56
Nächste Seite
6
A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
Fig. 2 - NORM SURF MAIN
Fig. 1 - DIAGNOSTIC
OVERVIEW
The A300 model features FREE Dive mode as well as NORM, TECH, and GAUG modes.
The A300xt model features a Tank Pressure alarm (actuated by an reed switch) for an analog pressure
gauge mounted in the same console as the dive computer module.
NORM mode is intended for the casual diver who plans to use a single gas and does not yet wish to
configure the numerous settings and alarms, many are factory set at predetermined fixed values.
TECH mode allows the user to configure all settings and alarm values using the control buttons or PCI
program, and set up and switch between multiple gasses.
GAUG mode is for those using the units as digital gauges with no Ni-O2 calculations.
FREE mode (A300 only) is for those using the unit for breath hold activities without scuba.
ACTIVATION & DIAGNOSTICS
A momentary press/release of any button will activate the unit. It will not activate at a depth deeper
than 5 FT (1.5 M) or at an Altitude higher than 14,000 feet.
The unit has contacts that will cause it to activate and enter Dive Mode upon descent to 5 FT (1.5 M)
for 5 seconds.
The contacts are the buttons and the pins of the PCI (PC Interface) data port. Conductivity between
any button and any pin (being wet) will satisfy the activation bridge.
Upon wake up, the unit will check for depth once per second. If depth is not sensed within 10 minutes,
it will enter PSM (Power Saver Mode). Once a dive is made, it will continue checking for depth until
the Time to Fly and Time to Desaturate counters reach 0:00 (hr:min), 24 hours post dive max, and the
unit shuts Off.
Immediately following manual (push button) activation (not if by wet activation), all segments of the
LCD are displayed (Fig. 1) followed by a countdown from 8, -, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0 (approx 3
sec). If sensor readings and battery voltage are within tolerance, the NORM Surface Main screen is
displayed (Fig. 2).
If any value is not acceptable, the failure description will flash for 5 seconds for each type failure. If
more than one failure is sensed, the failures will be presented sequentially in the following order.
EEP >> Eeprom error; CAL >> Calibration error; ALT >> higher than 14000 feet or deeper
than 5 feet; BAT >> Battery voltage too low (icon flashing); A-D >> A/d over range
Once the unit is activated, regardless of what mode it is in, it will enter the selected Dive Mode upon
descent to 5 FT (1.5 M) for 5 seconds.
By accessing the Set OP MOD selection (Fig. 3) in the SET group, the Operating Mode can be
changed from NORM to TECH, GAUG, or FREE (A300 only).
Once a mode is selected, operation remains in that mode until changed.
Once a dive is made in GAUG mode, operation locks into GAUG for 24 hours after surfacing.
While the Surface Main screen is displayed, access to other modes and screens is allowed. They will
remain on display for 2 minutes or until a button is pressed to access another mode or screen.
Fig. 3 - TO ACCESS SET
OPERATING MODE
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aeris A300 XT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info