A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
NORM/TECH SURF ALT 3 (only if Nitrox, no screen if Air), information includes (Fig. 11):
> Current O2% saturation with icon.
> Current FO2 set for Gas 1 with FO2, Gas 1, & NX icons.
> Current PO2 alarm value set for Gas 1 with icon, fixed at 1.40 if NORM.
A (< 2 sec) to step forward to FLY.
M (< 2 sec) to step back to ALT 2.
10 sec, or M (2 sec), revert to Main.
S (press) to activate Backlight.
- - - - - - - - - -
During the first 10 minutes on the surface after a dive, the ALTs can be accessed, other screens cannot.
- - - - - - - - - -
FLY/DESAT
FLY Time is a count down timer that begins counting down 10 minutes after surfacing from a dive from 23:50 to 0:00 (hr:min).
DESAT Time, also a count down timer, provides calculated time for tissue desaturation at sea level taking into consideration the
Algorithm used and the Conservation Factor setting.
DESAT Time also begins counting down 10 minutes after surfacing from a NORM dive, counting down from 23:50 (max), usually
much less, to 0:00 (hr:min).
When the DESAT time reaches 0:00, which will generally occur prior to the FLY count down reaching 0:00, it will remain on the
display until the FLY count down reaches 0:00.
> Desaturation requiring times greater than 24 hours will display 23: - - .
> In the event that Time to Desaturate still remains at the end of 24 hours, the added time will be zeroed.
> When other screens are accessed, the FLY and DESAT countdowns continue in the background.
Fly/Desat, information includes (Fig. 12):
> Time to Fly countdown (hr:min) with FLY and clock (time) icons, dashes if no dive yet.
> Time to Desaturate countdown (hr:min) with SAT and clock (time) icons, dashes if no dive yet or a Violation dive, blank after
a GAUG dive.
A (< 2 sec) to step forward to Plan Lead-in.
M (< 2 sec) to step back to ALT 3 if Nitrox, or to ALT 2 if Air.
2 minutes, or M (2 sec), revert to Main.
S (press) to activate Backlight.
NORM/TECH PLAN MODE
No Deco time Limits (NDLs) and O2 time Limits (OTLs) in Plan Mode are based on the Algorithm selected (DSAT or Z+), the FO2
set for Gas 1, and residual nitrogen (or O2) remaining from previous dives. FO2 set for Gas 2 or 3 (TECH only) are not used for
Plan calculations.
PDPS (Pre Dive Planning Sequence)
Plan screens will sequence through Depths from 30 to 190 FT (9 to 57 M), or the Max Depth that will allow theoretical No Deco
Dive Time of at least 1 minute based upon the previous dive profiles in a series of repetitive dives and taking into account descent
and ascent rates of 60 FPM (18 MPM).
When the Conservative Factor is set On, NDLs are reduced to the values of the next 3,000 foot (915 meter) higher Altitude.
Refer to tables in back.
Plan Lead-in, information includes (Fig. 13, 14):
> Z+ (or DSAT), CF, NX icons, if they apply.
> Graphic PLAN if Air, or -
Max Depth allowed for Gas 1 FO2 setting with FT (or M) and MAX icons if Nitrox.
> Graphic AIR with FO2 and Gas 1 icons, or -
FO2 set for Gas 1 (xx%) with FO2 icon, and PO2 alarm setting (x.xx ATA) with PO2 icon if Nitrox.
> Plan mode icon (wave/clock/profile).
S (< 2 sec) to access PDPS.
A (< 2 sec) to forward to Log Lead-in.
M (< 2 sec) to step back to Fly/Dsat.
2 minutes, or M (2 sec), revert to Main.
Fig. 12 - FLY/DESAT
Fig. 13 - PLAN LEAD-IN
(Gas 1 set for Air)
Fig. 11 - NORM/TECH
SURF ALT 3
Fig. 14 - PLAN LEAD-IN
(Gas 1 set for Nitrox)
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aeris A300 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info