618065
15
Zoom out
Zoom in
Vorherige Seite
1/56
Nächste Seite
15
A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
TECH SET GAS 2 (3 similar), information includes (Fig. 29):
> SET, FO2, Gas (tank) 2 icons.
> CF, Z+ (or DSAT) icons, if they apply.
> Graphic AIR (or OFF*) flashing, or -
. . Max Depth allowed with FT (or M) and MAX icons.
. . FO2 (numeric) value flashing.
Since there are only 2 digits, 100% is displayed as 00.
. . PO2 Alarm value with PO2 icon.
*OFF will prevent that Gas from being displayed as a switch option during dives.
A (hold) to scroll upward through FO2 settings from OFF (if previously selected) to Air to 21 through 100% in 1% increments
at 8/sec, stopping when the button is released, or at 32, then at 50, then at 80 (even if A is held depressed).
A (hold) again to resume the scroll upward through 100%, then stop at Air (or 21 if a repetitive Nitrox dive).
A (< 2 sec) to step upward through the Set Points one at a time.
M (< 2 sec) to step back through the Set Points one at a time.
S (2 sec), if the setting is not changed, to step back to Set Gas Lead-in.
2 minutes, or M (2 sec), revert to Main.
S (< 2 sec) to save the setting and flash the PO2 digits if Nitrox, or access Set Gas 3 if Air.
To set PO2, if flashing -
A (< 2 sec) to step upward through the Set Points of 1.00 to 1.60 one at a time in increments of 0.05.
M (< 2 sec) to step back through the Set Points one at a time.
S (< 2 sec) to save the PO2 Alarm setting and access Set Gas 2 (revert to Set Gas Lead-in after Gas 3).
S (2 sec) to step back to Set Gas Lead-in.
2 minutes, or M (2 sec), revert to Main.
NORM/TECH SET ALM (ALARMS)
Unless noted otherwise, Alarm values set in one mode also apply to the other mode. Example: If the Audible is set OFF while in
NORM mode, it can then be set ON while in TECH mode.
SET ALM LEAD-IN, information includes (Fig. 30):
> Graphics Go To and ALM with SET icon.
S (< 2 sec) to access Set Audible.
A (< 2 sec) to step forward to Set UTL Lead-in.
M (< 2 sec) to step back to Set GAS Lead-in.
2 minutes, or M (2 sec), revert to Main.
SET AUDIBLE ALARM, information includes (Fig. 31):
This feature is used to disable Audible Alarms and the associated LED, except during Violations. Setting it Off does not effect the
messages or flashing that occurs when an Alarm strikes. It also does not affect FREE Mode Alarms (A300).
> Graphic AUD with SET icon.
> Graphic OFF (or ON) flashing.
A or M (< 2 sec) to toggle between OFF and ON.
S (< 2 sec) to save the setting and access Set Depth Alarm.
S (2 sec), if the Set Point is not changed, to step back to Set ALM Lead-in.
2 minutes, or M (2 sec), revert to Main.
SET DEPTH ALARM, information includes (Fig. 32):
This feature is not the same as the Delayed Violation depth alarm, or the FREE depth alarms (A300), described later.
> SET icon.
> Graphic OFF (or ON) flashing, with Depth value last set with FT (or M) and MAX icons solid.
A (< 2 sec) to step forward through the selections OFF, ON, and SET.
M (< 2 sec) to step back through the selections.
S (< 2 sec) to save the selection and access Set EDT Alarm if OFF or ON is saved, or flash the Depth digits if SET is saved.
S (2 sec), if the selection is not changed, to step back to Set Audible.
2 minutes, or M (2 sec), revert to Main.
If SET is saved and the Depth digits are flashing >>
A (hold) to scroll upward through the Set Points from 30 to 330 FT (10 to 100 M) in 10 FT (1 M) increments at 8/sec.
A (< 2 sec) to step upward through the Set Points one at a time.
M (< 2 sec) to step back through the Set Points one at a time.
S (< 2 sec) to save the Depth value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
S (2 sec), if the Set Point is not changed, to step back to Set Audible.
2 minutes, or M (2 sec), revert to Main.
Fig. 29 - SET GAS 2
(Gas 3 similar)
Fig. 30 - SET ALARMS
LEAD-IN
Fig. 31 - SET AUDIBLE
Fig. 32 - SET DEPTH ALARM
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aeris A300 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info