587614
29
Zoom out
Zoom in
Vorherige Seite
1/118
Nächste Seite
29
English
IFCW3LJ 1210 - 5375700_01
• EUROVENT Certification
The response to the commands is
immediate if the room temperature
and the temperature of the water in
the system so allows
Tangential three-speed fan assembly
Very quiet operation
• Aesthetic design
Cream colour
Display on panel front
Horizontally adjustable discharge air
blades
• Horizontal deflector blades to
vertically adjust discharge air.
Manually adjustable only for units
without microprocessor controller.
For units with microprocessor
controller adjustable only via PFW2
wired control panel or TLW2 remote
control
Ease of installation with hydraulic
and condensate drain connections
adjustable in several directions
Routine maintenance is limited to
periodic cleaning of the air filter
Full compliance with safety
regulations.
FCW WALL-MOUNTED FAN COIL UNIT
The fan coil unit is a terminal unit for
conditioning internal air both in winter
and summer.
The FCW fan coil unit for wall
mounted installation concentrates high
technological and functional charac-
teristics that make it the ideal climate
control unit for all environments.
The supply of climate controlled air
is immediate and distributed through-
out the room; FCW generates heat if
included in a heating system with a
boiler or heat pump but may also be
used in the summer as an air condi-
tioner if the system has a water chiller.
The fan coil unit is designed to ensure
maximum compliance with safety
regulations.
Several versions of FCW fan coil units
are available in order to satisfy all
types of installations:
- with internal 2-way-valve,
- with internal 3-way-valve
- without valve.
Each version is available:
- With microprocessor controller
(requires the addition of the PFW2
wired control panel accessory or the
TLW2 remote control accessory.)
- Without microprocessor controller
which then requires a cable
connected accessory panel or
connection to the accessories of the
VFM system (the VMF-E0 and VMF-
E1 thermostats cannot be installed
internally to the fan coil unit).
In particular, the possibility to be
integrated into the VMF system allows
the control of a single fan coil unit
with accessories, up to the control of
the fan coil unit installed in a complex
network.
By choosing the appropriate options it is possible to select the model to suit the specific system requirements:
Unit configuration
1 2 3 4 5 6 7 8
Code
FCW
Size
21
31
41
Valve
2V (2-way valve fitted inside)
3V (3-way valve fitted inside)
VL (without valve)
Microprocessor Controller
(Blank) with controller
N without controller
2V version with 2-way valve fitted
inside.
Microprocessor controller.
Wired control panel PFW2 or remote
control TLW2.
2VN version with 2-way valve fitted
inside.
Standard control or VMF System.
3V version with 3-way valve fitted
inside.
Microprocessor controller.
Wired control panel PFW2 or remote
control TLW2.
3VN version with 3-way valve fitted
inside.
Standard control or VMF System.
VL without valve version.
Microprocessor controller.
Wired control panel PFW2 or remote
control TLW2.
VLN without valve version.
Standard control or VMF System.
MAIN CHARACTERISTICS:
Versions
The Aermec FCW fan coil unit is made with materials of superior quality in strict compliance with safety regu-
lations. The "FCW" is easy to use and will have a long life.
29

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aermec FCW 213V wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info