MAIN FUNCTIONS
• Make sure the unit is turned off and unplugged before handling.
• Do not immerse the device in water or any other liquid.
• Do not use corrosive, abrasive or flammable products to clean the unit.
CLEANING THE TANK: To avoid scale deposits, clean the tank at least once a month with a
suitable product or white vinegar. To do this, remove the tank from the unit and remove the
cap, then ll it with water and cleaning agent. Let stand for 15 minutes, then empty and rinse
the tank thoroughly with clean water before putting it back in place and turning on the device
again.
CLEANING ULTRASONIC PLATE : Dry the ultrasonic plate and clean it with a soft brush. Then wipe
it with a soft cloth.
STOCKAGE: To avoid any bacteria or virus proliferation, never store the appliance with water
inside the tank and be sure that the appliance is perfectly dry. Never leave water in the tank
when the unit is not used.
1. Empty and clean the tank.
2. Clean the pre-lter.
3. Store the product in a place that is protected against dust and that is clean and dry.
AUTOMATIC AIR HUMIDIFICATION
C [POWER] FUNCTION: SOLNAN is equipped with 3 levels of diffusion power, allowing to in-
crease the speed of air humidification and to regulate the intensity of the mist. The corres-
ponding number appears on the digital display:
1 – Low power
2 – Medium power
3 – High power
When the digital display indicates the ambient humidity rate, press it once to increase the
preset power. Press it a second time to change the power.
At full power, the mist produced may condense around the appliance and give the impres-
sion of a tank leak. To avoid this phenomenon, reduce the diffusion power and/or place the
humidifier towards a heat source (at about 1 meter).
B [TIMER] FUNCTION: This function allows you to choose the operating time of your appliance,
from 1 to 12 hours.
1. By pressing button B, the digital display indicates “01” for “1 hour of operation”. Press the
button repeatedly to reach the desired value.
2. Without any action on your side, the digital timer display stops flashing after 5 seconds,
which means that the setting is successful.
3. Once the desired operating time is set up, the digital display indicates the remaining time
every minute, and decreases from hour to hour. If you have set the Timer to “03" (3 hours),
the digital display will indicate “02" after one hour of operation.
To cancel the Timer setting, hold down button B for 2 seconds.
D [HYGROSTAT] FUNCTION: This function allows you to set up the ambient humidity rate to the
value you want (between 30 and 90%). For maximum comfort, we recommend a humidity
rate between 45 and 55%.
1. Before pressing button D, the digital display indicates the ambient humidity rate.
2. Press button D, several times to select the value you want. The value increases in steps
of 5%.
3. Without any action on your side, the digital hygrostat display stops flashing after 5 se-
conds, which means that the setting is successful.
4. Once the desired humidity rate is set up, the digital display indicates this rate every mi-
nute, flashing slowly.
Set up of the appliance in CONTINUOUS mode:
To activate this function, press several times the button D until the “CO” acronym appears.
After 5 seconds, the digital display indicates again the ambient humidity rate.
Caution: By selecting the [HYGROSTAT] function, it is not possible to adjust the power of the
appliance.
MAINTENANCE
SOLNAN is equipped with an [HYGROSTAT] function that allows you to choose a desired humi-
dity rate in your room. By making this setting, the appliance will automate its operating.
Desired humidity rate according
to the ambient humidity rate Automatic humidication power
Higher than 16% or more 3 – High power
Higher than 10 to 15% 2 – Medium power
Higher than 1 to 9% 1 – Low power
Lower The appliance is in standby
NIGHT MODE: You can activate or deactivate the LED display of the appliance:
1. Hold down the button D for 2 seconds: the blue LED situated under the appliance and the
digital display turn off.
2. Press one of the buttons to reactivate the digital display.
3. Press again one of the buttons to modify the operating mode of the appliance.
4. Hold down the button D again to reactivate the LED lights.
16 17
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Air and Me Solnan wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info