Professional Digital raDon Monitor User ManUal
KEY TO FIGURE
Reset Mode
1 7
10 11
12
13
8
6
8
2
3
3
4
5
9
7. The unit is active when
ashing
8. Unit of measurement: pCi/L
9. USB connection
10. ‘RESET. Used to start a new
measurement period.
11. ‘MODE’. Displays the number
of days measured since the
previous reset.
12. Battery compartment for 3 x
LR03, alkaline AAA batteries
13. Opening the battery cover
1. Indicator for low battery level.
Replace batteries when lit.
2. ‘LONG TERM AVERAGE
measurement mode
3. Measured value
4. ‘SHORT TERM AVERAGE
measurement mode
5. Measurement period for short
term average. Alternates between
1 and 7 days
6. Indicator for USB connection
to PC
SPECIFICATION
Sampling Method
Detection Method
Power Supply
Dimensions (in)
Weight (lbs.)
Operation Environment
Temperature
Relative Humidity
Measurement Range
Monitor
Upper display limit
Measurement precision
7 days
1 month
Measurement accuracy
Diffusion time constant
Internal memory
storage capacity
Temperature sensor
Range
Resolution
Accuracy
Humidity sensor
Range
Resolution
Accuracy
Barometric pressure sensor
Range
Resolution
Accuracy
Passive radon diffusion chamber
Alpha spectrometry
3 AAA alkaline battery (LR03)
> 18 months battery life-time
4.7 x 2.7 x 1.0
0.3 (incl. batteries)
39 °F to 104 °F
<85 % RH
0 - 1 000 pCi/L
500 pCi/L
<12 % at (1.3 - 10.0) pCi/L
<8 % at >10.0 pCi/L
<9 % at (2.5 - 6.0) pCi/L
<6 % at >6.0 pCi/L
± 0.15 pCi/L below 3.0 pCi/L
± 5 % above 3.0 pCi/L
25 minutes
10 years at 1h time resolution
39 °F to 104 °F
1 °F
± 1 °F (typical)
5 % RH to 85 % RH
0.5 % RH
± 4.5 % (in range 20-80 % RH)
50.0 kPa to 115.0 kPa
0.06 kPa
± 1 kPa
SAFETY
Contact the seller if the product requires service or
repairs. The front or back cover must not be opened.
Avoid subjecting the unit to shock, impact, pres-
sure, vibrations, dust and moisture. Condensation
can occur if the unit is moved from a location with
high atmospheric humidity to a cold location. If
condensation occurs, remove the batteries and
leave the unit in a dry environment for 2 hours.
The unit must not be exposed to direct sunlight
for extended periods. The monitor must be stored
under dry conditions.
Use only batteries of type LR03, alkaline AAA bat-
teries. The batteries must not be exposed to re or
other extreme heat. The battery terminals must not
be touched, and they must be kept free from dust,
sand, liquids and other foreign objects.
LIFETIME
The monitor is tested and quality assured by pro-
ducer. It is recommended that the monitor is pow-
ered continuously, and that the batteries replaced
when its low level is indicated on the display.
NOTE: The monitor meets the specied accuracy,
unless it continuously measure high radon levels
(hundreds of pCi/L) over years.
GETTING STARTED
Insert the supplied batteries. Please observe
correct polarity of your batteries and make sure
you install them in the correct orientation as
advised by the marking in the bottom of the bat-
tery compartment. The display shows a 30 second
start up sequence when the batteries are inserted
(or after a RESET). Then, both the sampling of
the indoor air and the radon level calculation
are started. In this phase the display shows from
4 to 1 ashing dashes indicating how long it is
left to the monitor begins to show radon levels.
Depending on the radon level this phase will
take from 6 to 24 hours. The rst days the result
must only be considered as an indication of the
radon level. The precision of the measurement
increases with longer measurements.
A measurement is started by:
- inserting the batteries OR
- pressing RESET button.
The monitor is self-testing for a few minutes after
the start.
The unit should not be exposed to direct sunlight
or electromagnetic radiation; it should be posi-
tioned lying at at least 10" from the nearest wall,
at least 19" above the oor, and at least 60" from
the nearest door, window or ventilation device.
The RESET and MODE buttons should be pressed
with a ball-point pen or similar.
HOW TO USE THE MONITOR
The long term average (LONG TERM AVERAGE)
is the average radon value since last reset or
average for last 12 months if one has measured
more than 12 months (updated once every 24
hours).
The short term average (SHORT TERM AVERAGE)
alternates between showing the radon value
over the last day (1 DAY – updated every hour)
and over the last 7 days (7 DAYS – shown after
1 week and updated once every 24 hours).
The long term average is used to identify any po-
tential health risk , and for continuously monitor-
ing that any installed mitigation measures works
properly. The short term average is used primarily
to see the effect of measures to reduce the radon
level – for example by increasing the ventilation.
The building can be diagnosed by taking measure-
ments for one week. This should preferably be
followed by long term measurement in the room
which has the highest radon value. For long term
measurement period and action level it is recom-
mended to follow the guidelines from the national
radiation authority.
When the monitor is moved to another room, a new
measurement should be started (RESET).
The MODE button when pressed once, it will display
the number of days of the on-going measurement:
since the last RESET or since the Power ON. This
information is displayed on the lower half of the
screen for 20 seconds, after which the screen re-
verts to the regular display.
When the monitor is connected to PC with the
USB cable, it displays the connection indicator and
the last digits of its serial number. Read the User
Manual of the CRA software. It is a tool for detailed
analysis of the measurement results.
RESPONSIBILITY
The monitor and the batteries must not be dis-
posed of as ordinary household waste. It is the
users environmental responsibility to ensure that
electronic equipment and batteries are disposed
of in accordance with national regulations. Users
should contact the seller or their local authority
for information about environmentally friendly
waste disposal.
Corentium plus has a 1-year warranty against sys-
tem failure. In the event of incorrect use or opera-
tion of the monitor, Airthings AS cannot be held
responsible for any losses resulting from failure or
from the loss of measurement data.
Corentium® is a registered trademark
of Airthings AS.
Airthings AS, Oslo, Norway. v 1.0
© 2016 Airthings AS. All rights reserved.
Treehouse 14004-05-2-010

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Airthings Corentium Plus wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info