CONNECT THE INDOOR TO THE OUTDOOR UNIT
The indoor unit contains a small quantity of nitrogen. Do
not unscrew the nuts from the unit until you are ready to
connect the tubing. The outdoor unit is supplied with
sufficient refrigerant charge (R410A). Refer to outdoor unit
nameplate.
To prevent crushing, bend tubes using a bending tool.
REFRIGERANT TUBING
NOTE: Use refrigeration type copper tubing only.
2. Use tubing diameter that corresponds to the tubing
diameter of the indoor and outdoor units. Note that the
liquid and suction tubes have different diameters. (See
tube size, torque tightening table.)
3. Place flares nuts on tube ends before preparing them
with a flaring tool. Use the flare nuts that are mounted
on the supplied outdoor and indoor units.
4. Connect the all ends of the tubing to the indoor and
outdoor units.
5. Insulate each tube separately, and their unions, with at
least 13 mm thick of insulation. Wrap the refrigerant
tubing, drain hose and electric cables together with a
vinyl tape (UV protected).
R410A
1. Open the valve cover.
Notice the sign. All ends should
correspond one by one.
Caution!
When unscrewing the
valve caps, do not stand
in front of them or the
spindles at any time, as
the system is under
pressure.
Tightening
torques of unions
and valve caps:
TUBE SIZE
Liquid line 1/4"
Suction line 3/8"
Suction line 1/2"
Suction line 5/8"
TORQUE
15-20 N.M.
30-35 N.M.
50-54 N.M.
75-78 N.M.
Fig.9
1.Wrench
2.Torque wrench
3 Union.
Fig.10
To prevent refrigerant
leakage, coat the flared
surface with
refrigeration oil
Fig.11
1.Suction valve
2.Service port
3.Liquid valve
Fig.8
1.INDOOR UNIT
2.Liquid tube (small dia.)
3.Suction tube (large dia.)
4.Plugs
5.Flare nuts
6.Tubing between units
7.Suction tube
8.Liquid tube
9.OUTDOOR UNIT
10.Flare nuts
11.Suction valve (larger)
12.Liquid valve (small)
EVACUATION OF THE REFRIGERATION TUBES AND THE
INDOOR UNIT
After connecting the unions of the indoor and outdoor units,
purge the air from the tubes and indoor unit as follows:
5. Cap
6. Suction valve
7. Service valve*
8. Cap
9. Liquid valve
10. INDOOR UNIT
11. Suction flare connection
12. Liquid flare connection
*In some models only
Fig 12
Fig.12
1. Charging set
2. Vacuum pump
3. OUTDOOR UNIT
4. Service valve
NOTE
For additional
charge of various
tubing lengths,
refer to outdoor
unit nameplate.
1. Connect the charging hoses with a push pin to the low side
of the charging set and the service port of the suction valve.
Be sure to connect the end of the charging hose with the
push pin to the service port.
2. Connect the center hose of the charging set to a vacuum
pump.
3. Turn on the power switch of the vacuum pump, turn off the
high side switch and make sure that the needle in the gauge
moves from 0 MPa (0cm Hg) to -0.1 MPa (-76cm Hg). Let
the pump run for fifteen minutes.
4. Close the valve of the low side of the charging set and turn
off the vacuum pump. Note that the needle in the gauge
should not move after approximately five minutes.
5. Not any problem for five minutes, turn on the power switch of
the vacuum pump and open the valve of the low side of the
charging set.
6. Disconnect the charging hose from the vacuum pump and
from the service ports of the suction valve.
7. Tighten the service port caps of suction valve.
8. Redo 1 to 7 for other indoor units.
9. Remove the valve caps from all valves, and open them
using a hexagonal Allen wrench.
10. Remount valve caps onto all of the valves.
11. Check for gas leaks from all the connecting position. Test
with electronic leak detector or with a sponge immersed for
soapy water for bubbles.
NOTE: 1# valves connect IDU-1.
2# valves connect IDU-2.
All ends should correspond one by one.
Fig 8
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Airwell Multisplit YAZE DUO DCI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info