601646
15
Zoom out
Zoom in
Vorherige Seite
1/188
Nächste Seite
Assembly
467 776_a 15
Damaged or brittle extension cables must not
be used.
Check the condition of your extension
cable each time you start to use the
equipment.
ASSEMBLY
Erecting the equipment
1. Prepare a flat and solid erection site.
2. Erect the machine horizontally and protected
against flooding.
3. Bolt the house water system securely at the
bolting points (Fig. A -7) if necessary.
4. The house water system must be protected
from rain and direct water jets.
ADVICE
In daily operation (automatic mode), you
must ensure, by suitable measures, that,
in the event of a fault in the equipment,
consequential damage caused by floo-
ding is excluded.
Connecting the suction line
1. Select the length of the suction line (Fig. B
-18) to make sure that the house water sys-
tem cannot run dry. The suction line must al-
ways be at least 30 cm under the surface of
the water.
2. Connect the suction line. Make sure that the
connection is tight, but do not damage the
thread.
We recommend using flexible lines at the
pump inlet (Fig. A -11). This ensures that
pressure or tension on the house water
system cannot be exerted.
3. If the water has a small amount of sand in it,
a pre-filter must be fitted between the suction
line and the pump inlet. Ask your expert dea-
ler about this.
4. Always lay the suction line with an upward
gradient.
ADVICE
If the suction height is more than 4m, you
must use a suction hose having a diame-
ter greater than 1". We recommend the
use of an AL-KO suction unit with suction
hose, suction filter and flow-back stop.
Ask your expert dealer.
Fitting the pressure line
1. Screw the connecting nipple (Fig. B -16) with
the round seal ring (Fig. B -17) into the pump
outlet (Fig. A -4).
2. Screw the elbow nipple (Fig. B -14) with seal
(Fig. B -15) onto the connecting nipple (Fig. B
-16) and turn the elbow nipple in the desired
direction.
3. Fix a pressure line (Fig. B -13) onto the elbow
nipple (Fig. B -14).
4. Open all the closing off devices (valves, spray
nozzles, water cock) in the pressure line.
STARTUP
Check the air pressure in the storage vessel
CAUTION!
The house water system must only be
commissioned with a storage diaphragm
pressure of 1.5 - 1.7 bar in the storage
vessel. Check the air pressure at the
valve on the back of the storage vessel
before commissioning.
1. If necessary, in the pressure line (Fig. B -13),
open one of the existing closing off devices
(valve, spray nozzle, water cock).
2. Slide the closing off cover valve (Fig. F -28)
on the back of the storage vessel (Fig. A -6)
upwards.
3. Check the air pressure at the valve (Fig. F -29)
with an air pump or a tyre filler, each having a
pressure indicator (pressure gauge).
4. If necessary, adjust the air pressure to 1.5 -
1.7 bar.
5. Then close the closing off cover valve on the
back of the storage vessel again.
6. The house water system can now be commis-
sioned.
Filling the house water system
CAUTION!
Before commissioning, the house water
system must always be filled up to the
overflow with water, so that it can draw
water immediately. If the pump runs dry
it will be destroyed.
ADVICE
Fill the suction hose with water before
screwing in place to reduce the suction
time.
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

al-ko-hw-4000-fcs

Suche zurücksetzen

  • pumpe läuft nicht mehr und es zeigt auch keine Kontrolle an
    Eingereicht am 29-7-2017 10:39

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Al-ko HW 4000 FCS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info