Startup
16 HWA 4000 / 4500 FCS
1. Open the filling screw (Fig. A -3) with the filter
key (Fig. C -19/A).
2. Fill with water via the filling screw until the
pump housing (Fig. A -2) is full.
3. Screw the filling screw in.
Switching the pump on
1. Open one of the closing off devices (e.g. water
cock) in the pressure line.
2. Insert the mains plug on the connection cable
into the plug socket.
The pumps starts to feed.
3. When no more air comes out with the water,
close the closing off device in the pressure
line.
The pump switches off automatically af-
ter the switch-off pressure has been re-
ached. The house water system is ready
for operation.
The LED displays are off.
If water is being fed, just the LED display
PUMP ON lights up.
Initial commissioning
In the initial commissioning, the LED displays
PUMP ON and the LED display FLOW CONTROL
flashes.
ADVICE
If no water is being drawn up via the suc-
tion line after approx. 90 seconds, the dry
running protection system switches the
pump off and the LED display ALARM
lights up. Check for leaks in the suction
line, the filter glass and all screwed fit-
tings, push the RESET button and re-
peat the initial commissioning process.
Switch the pump off
1. Remove the mains plug from the socket
2. Close one of the closing off devices (valve,
spray nozzle, water cock) in the pressure line
(Fig. B -10).
ADVICE
If no suction takes place within a period
of 180 seconds, the garden pump au-
tomatically goes to "fault" condition and
switches off.
CAUTION!
Danger of injury from hot water
In extended use against the closed pres-
sure side (>10 min.), the water in the
pump can be severely heated up and can
be emitted in an uncontrolled manner!
Isolate the unit from the mains and allow
the pump and water to cool down. Start
the unit again only after all the faults have
been rectified!
The risk of injury from hot water can arise if:
the installation is not correct
the pressure side is closed off
there is a lack of water in the suction line, or if
the pressure switch is defective.
Procedure
1. Isolate the unit from the mains and allow the
pump and water to cool down.
2. Check the unit, the installation and water le-
vel.
3. Start the unit again only after all the faults
have been rectified!
MAINTENANCE AND CARE
Check the air pressure in the storage vessel
CAUTION!
Check the air pressure in the storage
vessel at regular intervals. It must not ex-
ceed 1.5 bar (see Section "Commissio-
ning: Checking the Air Pressure in the
Storage Vessel").
Cleaning the pump
ADVICE
After conveying swimming pool water
containing chlorine or fluids that leave a
residue, the pump must be flushed out
with clear water.
1. Isolate the unit from the mains and secure
against switching on again.
The pump stops automatically.
2. Flush the pump out with clear water.
3. Insert the mains plug into the plug socket.
4. Switch the house water system on with the
on /off switch (Fig. A -6).
The pump starts automatically.
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

al-ko-hw-4000-fcs

Suche zurücksetzen

  • pumpe läuft nicht mehr und es zeigt auch keine Kontrolle an
    Eingereicht am 29-7-2017 10:39

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Al-ko HW 4000 FCS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info