14 JET 4000 / JET 5000 / JET 6000
Inox stainless steel
Units marked with the designation "INOX" are
supplied in stainless steel. The structure and func-
tion are unaffected by this.
Designated use
The garden pump is intended for private use in
house and garden. It must only be used in the
framework of the deployment limitations in accor-
dance with the technical data.
The garden pump is suitable for:
Watering and irrigating
Re-pumping and pumping out of vessels (e.g.
swimming pools)
Water extraction from streams, rainwater
butts and cisterns.
The garden pump is is suited exclusively for the
conveying of the following fluids:
Clear water, rainwater
water containing chlorine (e.g. swimming
pools)
Any other use shall be regarded as misuse.
Possible misuse
The garden pump must not be used continuously.
They are not suitable for conveying:
Drinking water
Salt water
Waste water
Foodstuffs
aggressive media, chemicals
corrosive, flammable, explosive or fuming
fluids
Fluids that are hotter than 35 °C
water containing sand and abrasive fluids.
SAFETY INSTRUCTIONS
CAUTION!
Danger of injury!
Only use the machine and the extension
cable if it is in perfect technical condition!
Damaged units must not be used.
Safety and protective devices must not
be deactivated!
Children, or people who are not familiar with
the operating instructions, are not allowed to
use the machine.
Never lift, transport or suspend the unit using
the connection cable.
Unilateral modifications or conversions of the
unit are prohibited.
Electrical safety
CAUTION!
Danger when touching voltage con-
ducting parts!
Disconnect the plug from the mains if the
extension cable is damaged or severed!
We recommend connecting a RCD (re-
sidual current operated device) having a
nominal residual current of < 30 mA.
The house mains voltage must agree with the
details quoted in the technical data, do not
use any other supply voltage.
The unit must only be operated with an
electrical installation in accordance with DIN/
VDE 0100, Part 737, 738 and 702 (swimming
pools). Protection must be provided by a 10 A
line protection switch and a RCCD (residual
current operated device) having a nominal re-
sidual current of 10/30 mA.
Use only extension cables that are suitable
for use outdoors - minimum cross-section 1.5
mm
2
. Cable drums should always be unrolled
completely.
Damaged or brittle extension cables must not
be used.
Check the condition of your extension
cable each time you start to use the
equipment.
ASSEMBLY
Setting up the equipment
1. Prepare a flat and solid location.
2. Erect the unit horizontally and safe from the
risk of flooding.
The unit must be protected from the rain
and direct water jets.
Mounting the pressure line
1. Screw the connecting nipple (Fig. B -15) with
the round seal ring (Fig. B -16) into the pump
outlet (Fig. A -3).
2. Screw the elbow nipple (Fig. B -13) with seal
ring (Fig. B -14) onto the connecting nipple
(Fig. B -15) and turn the elbow nipple in the
desired direction.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

al-ko-jet-5000-comfort

Suche zurücksetzen

  • Pumpe schaltet nach 20minuten ab und es richt nach Kunststoff Eingereicht am 29-6-2020 14:26

    Antworten Frage melden
  • nach schliesen der wasserendnahme pumpe schaltet nicht ab. mus jedes mal neu angeschalte werden Eingereicht am 16-8-2017 08:09

    Antworten Frage melden
  • Pumpe schaltet permanent aus Flow Controlleuchte blinkt Eingereicht am 28-3-2017 19:25

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Al-ko Jet 5000 Comfort wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info