This CO detector is not a replacement for smoke, fire or other detectors.
This detector cannot protect people with special medical conditions and might not prevent any
chronic health effects of carbon monoxide on the body. This is not a replacement for the correct
installation, use and periodic maintenance of combustion equipment, nor adequate ventilation of
spaces in which these devices are being used.
RECOMMENDED POSITIONING FOR THE COA-29:
Install the CO detector in a bedroom, a hallway near the bedroom or the area near a
combustion device (boiler, water heater, gas stove, etc.). Check whether the alarm can be
heard inside bedrooms.
In houses with multiple floors, it’s recommended to install a CO detector on each floor.
Install the CO detector at least 2 meters away from combustion devices, within the air flow
from the combustion device. In the case of smaller spaces (<4m³), the detector should be
installed outside these spaces.
Install the CO detector in spaces without open combustion devices, preferably 1.50m above the
floor and outside spaces without air flow. In bedrooms, install the detector at ‘face height while
sleeping’.
Install the detector on a spot where the weekly check can be performed easily.
AVOID THE FOLLOWING PLACES FOR INSTALLATION:
Never install the CO detector in spaces without air flow, such as roof ridges, arched ceilings or front
roofs.
Never install the CO detector in the turbulent air from ceiling fans, nor place it near vents with fresh
air or close to doors and windows opening to the outside.
Keep the CO detector away from extremely dusty, dirty or greasy spaces such as kitchens, garages
and heating spaces <4m
³
or pantries. Dust, grease and household chemicals can affect the sensor.
Install the CO detector at least 0.5 meters away from gas discharge lamps (halogen) because of
electronic interferences that can lead to false alarms.
Keep the CO detector away from humid and wet spaces. Do not use spray cans near the CO detector.
Never install the CO detector in spaces with temperatures lower than 0°C or higher than 45°C, and
the humidity higher than 90%RH.
Never install the CO detector behind curtains or furniture. Carbon monoxide must be able to reach
the sensor to ensure the sensor can properly detect carbon monoxide levels. NEVER place the CO
detector flat on a table or similar surface.
INSTALLATION INFORMATION:
Install the dector on a wall using plugs and screws or place it on a table. Insert the batteries into
the detector. The Status LED will briefly illuminate, the detector will emit a short beep tone and the
display briefly lights up. Now install the detector onto the mounting place and press the detector
down until correctly fastened. You can perform the first test by briefly pressing the test button, see
also paragraph “Testing and reset”.
USE:
The CO detector starts functioning after installing the batteries (High Energy Alkaline batteries
1.5V AA - LR6) and mounting the CO detector on the wall. The unit can only be placed onto the
mounting plate with the batteries in place. The green “POWER” LED will flash every 40 seconds
to indicate that the detector is working. When the sensor indicates an empty battery the detector
emits a short beep tone every minute, you should replace the batteries as soon as possible. When
these warnings start, the detector will continue to function correctly for at least 7 days. The table
below shows when the detector will sound the alarm.
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Alecto COA-29-7 Koolmonoxide melder wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info