USE, TESTING AND MAINTENANCE:
USE:
The gas detector is operational if the 9 volt battery is placed and the GA-10 is connected by adapter. You can only place
the detector on the ceiling plate if the 9 volt battery is installed. If the detector is operational the red LED will blink. After
calibration it will turn green.
Once gas is detected, the alarm will go off. A loud beep will sound and the red LED will blink continuously. Once the
gas dissipates, the alarm will stop automatically.
Testing:
By pressing the test key on the GA-10, the alarm can be tested to ensure it is still operational. Hold the key for at least 2
seconds. Operation is correct if the red LED blinks and a tone is audible. Preferably check the detector weekly. During
alarm state, the GA-10 will generate a tone of at least 85dB(A) sound pressure.
Hush function:
With this function, the alarm will be deactivated for 5 minutes. This function can be activated by pressing the button
once, shortly. The red LED will blink to indicate the alarm is silenced. After 5 minutes, the blinking will stop and the
alarm will be reactivated
ATTENTION:
If there is any doubt over the cause of an alarm, then assume the alarm is caused by a gas leak and evacuate the
premises as soon as possible.
Keep the gas detector away from small children.
During renovations, protect the gas detector against dust. It will lose it’s functionality if covered by dust.
Maintenance:
The GA-10 can be cleaned with a vacuum cleaner.
ENVIRONMENT:
Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out as
normal waste, but must be recycled as electrical waste.
SPECIFICATIONS:
Usage temperature .........................................................................5°C tot 50°C
Power ...............................................................................................12VDC, 200mA 9V DC backup
Alarm point ......................................................................................< 15% LEL
Sound level during alarm ................................................................85dB at 1 meter
PROBLEM SOLUTION
No sound during the test procedure
Note: Hold the test button several
seconds during a test.
1. Remove the detector from the ceiling plate and check if the battery
and adapter is properly connected.
2. Clean the gas detector.
The gas detector beeps every minute Replace the 9V battery and check the adapter.
The gas alarm regularly gives a false
alarm during cooking or during use of
the shower.
1. Clean the gas detector.
2. Move the gas detector to another location.
Green LED blinks every 30 sec. Device not connected on main power, but works on battery.
Red LED blinks The device is still warming up or hush mode is active.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Alecto GA-10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info