46 IDR-8 User Guide
Factory default unit settings
Unit name – iDR Unit Name
Network settings
DHCP – No
IP address – 192.168.0.1
Net mask – 255.255.255.0
PPP settings
Host IP address – 192.168.0.1
Client IP address – 192.168.0.2
User name – iDR
Password – A&H
Factory default configuration settings
Input channel names
I/P 1…. I/P 16
Output channel names
O/P 1…. O/P 16
Input group names
IP Grp 1…. IP Grp 8
Output group names
OP Grp 1…. OP Grp 8
Stereo selections
All mono
Communications option
A RS232 B SysNet
Scheduled events
None
Power-up patch
None
All patches empty
Factory default patch parameters
AMM
No active inputs
No active outputs
Threshold 7dB
Gate depth 40dB
Hold time 1s
NOM attenuation 3dB
Input delays
All 0ms
Output delays
All 0ms
Input faders, mutes, groups
Fader levels off
Mutes off
Group assignments none
Group levels 0dB
Input patchbay
XLR 1 to Channel 1….
XLR 8 to Channel 8
Expander 9 to Channel 9….
Expander 16 to Channel 16
Output patchbay
Channel 1 to XLR 1….
Channel 8 to XLR 8
Expander 9 to XLR 9….
Expander 16 to XLR 16
LCD
Line 1 – user text ‘Allen & Heath’
Line 2 – time
Mic preamps
Pad on
Gain +20dB (resulting gain 0dB)
+48V off
Limiter off
Monitor manager
Follow mouse / active window
Routing matrix
All cross points 0dB (on)
Signal generator
Signal type – sine wave
Frequency – 440Hz
Level - -30dB
Front panel soft keys
S1-S8 – input level control CH1-8
S9-S16 – output level control CH1-8
iDR-switch inputs
S1-S24 – unused
Front panel soft LEDs
L1-L16 – static LED off
L17-L24 – input source meters CH1-8
L25-L32 – output post limiter meters CH1-8
iDR-switch outputs
S1-S16 – static LED off
Input expander
S1-S8 – input source meters CH9-16
Output expander
S1-S8 – Output post limiter meters CH9-16