541363
41
Zoom out
Zoom in
Vorherige Seite
1/48
Nächste Seite
ML3000 User Guide 41
12
16
3
6
3
0
9
18
15
12
6
24
30
27
21
9
The Meterpod
The Console Meterpod
The ML3000 continues the Allen & Heath tradition
to provide full signal metering at key stages in the
signal chain. The channel LED meters give you
important signal information and multipoint peak
sensing. The meterpod displays all the post-fade
main output levels including groups, auxes, matrix
and main, as well the PFL/AFL metering of any
signal in the console.
The meterpod is a low profile, full length integral
design that cannot be removed. It has 11
illuminated moving coil VU meters and 3 LED bar
meters. The right hand VU meters can be switched
to display either Aux 5-8 or Matrix 1-4 outputs. For
example you could configure the console to display
Groups 1-4, LCR, and Matrix 1-4 on the meters in
front-of-house mode, or Aux 1-8, LR and Wedge in
stage monitor mode.
The 3 main output meters are duplicated on both
VU and LED bar meters so that the main or
PFL/AFL signals can be checked for average and
peak levels simultaneously. Bright red LEDs light
when an input PFL or output AFL has been
selected. The C meters switch to display the PFL
or AFL signals. The LR meters turn off when PFL
or AFL is active to avoid confusion.
MATRIX Meter Select. Press the METERS switch
in the master section to switch the right hand VU
meters to display the Matrix 1-4 rather than Aux 9-
12 output levels. The green LED in the meterpod
lights when matrix is selected.
Lamps
Three console lamp connectors are positioned on
the rear of the meterpod. Standard 4-pin right-
angled XLR gooseneck Littlites are recommended.
Plug the lamps in and bend the goosenecks up and
over the Meterpod to illuminate the control surface.
Meter Types
Both VU and LED bar types of meter are provided
on the ML3000. This gives you the best of both
average and peak metering.
VU Meter. The VU (volume unit) meter is an
established standard for measuring audio signals.
Unlike LED meters, it is easy to read under all
lighting conditions. This makes it well suited to
outdoor festival work. It has reasonably slow
dynamics (attack and release) and is therefore good
at displaying the average music programme. It is
not able to display fast peaks and transients. The
scale is restricted between –20 and +5 to provide
good resolution around average reading. A reading
of ‘0’ represents 0dBu at the main outputs. A PEAK
LED is included to warm when the signal is within
5dB of clipping. This has a fast response to catch
the transients.
LED Bar Meter. This meter
comprises a ladder of LEDs each set
to light when the signal reaches its
preset level. It has the advantage of
much faster dynamics and can show
the musical peaks and transients.
The scale is extended to read from a
low –30 to a very high +16 which
represents a peak warning 5dB before
clipping.
Three LED colours display signal
condition:
Green. Normal signal readings up to 0dB.
Yellow. Hot signal readings above 0dB and up to
12dB. Loud moments reading up to 6dB are fine.
Higher readings warn of reduced headroom.
Red. Lights at +16dB to warn that you are within
5dB of clipping and audible distortion. If this flashes
then reduce the gain or mix levels.
C
99
L
2121
R
27
30
24 24
30
27
6
12
15
18
9
0
3
6
3
6
9
18
15
12
3
6
3
0
16
12 12
16
9
21
24
30
27
6
9
18
15
12
3
6
3
0
12
16
1
MATRIX
2
MATRIX
3
MATRIX
4
MATRIX
PHONES
HEATH&ALLEN HEATH&ALLEN HEATH&ALLEN HEATH&ALLEN HEATH&ALLEN HE ATH&ALLEN HEATH&ALLEN HEATH&ALLEN HEATH&ALLEN HEAT H&ALLEN HEATH&ALLEN
MATRIX
AFL
PFL
HEATH&ALLEN
MTX 1-4
AUX 5-8
METERS
41

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Allen-Heath ML 3000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info