541414
102
Zoom out
Zoom in
Vorherige Seite
1/114
Nächste Seite
Glossary
90
CROSSOVER—Wiring used when connecting a 10BASE-T MAU to another 10BASE-T
MAU or a 10BASE-T hub to another 10BASE-T hub. For example, one 10BASE-T MAU
has the TD pair on the same pins as another 10BASE-T MAU. If pins were wired straight,
there would be two transmitters on one pair and no receiver. As a solution, the crossover
cable crosses the TD pair with the RD pair, to connect the TD pins on one end to the RD pins
at the other end.
CYCLIC REDUNDANCY CODE (CRC)—An algorithm used to check for and correct bit
errors in data transmission.
DATA COMMUNICATION EQUIPMENT (DCE)—In RS232 specification a module, such
as a modem, for connecting a DTE to other equipment. A repeater connected to a terminal
or workstation for OMEGA management use is wired as a DCE.
DATA TERMINAL EQUIPMENT (DTE)—In RS232 specification a module typically at
the end of a segment. The DTE could be an Ethernet workstation, repeater or bridge.
EMULATED LOCAL AREA NETWORK (ELAN)—See LAN Emulation.
FOIRL — A fiber optic standard that allows up to 1,000 meters (3,280 ft.) of multimode
duplex fiber optic cable in a point-to-point link.
HOT SWAPPING— The process of replacing a module without interrupting the network.
This process occurs by sliding an active module into a fully powered up unit, replacing a
failed module.
HOUSE WIRING—House wiring is the existing wiring inside a building. This wiring
generally originates from one or more wiring closets, such as a telephone room. Some older
buildings may have wiring unsuitable for 10 megabit data rates. In these circumstances, it
is recommended that the wiring be tested with a 10BASE-T signal/wire tester.
HUB/REPEATER—A hub is a central signal distributor. It is used in a wiring topology
consisting of several point-to-point segments originating from a central point. The term hub
is often used interchangeably with the term repeater. Multiport 10BASE-T, 10BASE2 and
fiber optic (10BASE-FL, FOIRL) repeaters are considered hubs. See Repeater.
HUB-TO-HUB WIRING—See MAU-to-MAU Wiring
HUB-TO-MAU WIRING—UTP cables for 10BASE-T hub-to-MAU or NIC cards are wired
straight-through. An RJ45 receptacle at the hub would wire pin-to-pin to the RJ45
receptacle at the MAU.
IMPEDANCE—An electrical characteristic of a circuit dealing with the combination of the
AC and DC resistance and the appearance of that resistance to attached circuits.
INTERIM LAYER MANAGEMENT INTERFACE (ILMI)—Protocol defined by the
ATM Forum UNI standards for managing the UNI.
JABBER LOCK-UP—The MAU’s ability to automatically inhibit the transmit data from
reaching the medium if the transmit data time exceeds a specified duration. This duration is
in the range of 20 ms to 150 ms. Jabber lock-up protects the medium from being overrun with
data packets from a possibly defective device.
JAM—This is a term used to describe the collision reinforcement signal output by the
repeater to all ports. The jam signal consists of 96 bits of alternating 1s and 0s. The purpose
is to extend a collision sufficiently so that all devices cease transmitting.
JITTER—The fluctuation of the data packet in respect to a standard clock cycle. Jitter is
undesirable and must be minimized.
LAN—See Local Area Network
LAN EMULATION—Methodology for mimicking the appearance of a LAN by rendering
the ATM switching fabric invisible to the user; enables user interface software to treat a
virtual LAN as if it were a physical LAN.
102

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Allied Telesis AT-TS95TR wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info