69160
18
Zoom out
Zoom in
Vorherige Seite
1/364
Nächste Seite
17
Water Filter
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge
Specifications
Service Flow Rate (Maximum).............................................0.78 GPM (2.9 L/min)
Rated Service Life 750 (Maximum) ...................................750 gallons/2838 liters
Maximum Operating Temperature .....................................100° F/38° C
Minimum Pressure Requirement........................................35 psi/241 kPA
Minimum Operating Temperature......................................33° F/ C
Maximum Operating Pressure.............................................120 psi /827 kPA
Performance Data
Timely replacement of filter cartridge is essential for
performance satisfaction from this filtration system.
Please refer to the applic
able section of your Use &
Care Guide for general operation, maintenance
requirements and troubleshooting.
This system has been tested according to ANSI/NSF 42
and 53 for reduction of the substance listed above. The
concentration of the indicated substances in water
entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving
the system, as specified in A
N
S
I
/NSF 42 and 53.
* Tested using a flow rate of 0.78 GPM; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of
68° ± 5° F (20° ± 3° C) under standard laboratory conditions, however, actual
performance may vary. Health Claim Performance tested and certified by NSF
International
** Measurement in Particles /ml. Particles used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity units
General Use Conditions
Read this Performance Data Sheet and compare the
capabilities of this unit with your actual water
treatment needs.
D
O NOT use this product where water is micro-
biologically unsafe or of unknown quality without
adequate disinfection before or after the system.
System certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK
FOR COMPLIANCE WITH THE STATE AND LOCAL
LAWS AN
D R
E
G
ULATIONS.
TM
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Taste & Odor
Mechanical Filtration Unit
P
articulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane, Mercury &
Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
Tested and certified by NSF International against ANSI/NSF Standards 42 & 53
in models 750 for the reduction of:
Parameter
C
hlorine
T
& O
Particulate**
U
SEPA
MCL
S
tandard No. 42: Aesthetic Effects
I
nfluent
Challenge Concentration
2
.0 mg/L ± 10%
at least 10,000 particles/ml
I
nfluent
Average
1
.88 mg/L
5,700,000 #/ml
Average
<
0.05 mg/L
30,583 #/ml
Maximum
0
.06 mg/L
69,000 #/ml
Average
>
97.26%
99.52%
Minimum
9
6.84%
98.94%
M
in. Required
Reduction
5
0%
85%
Effluent % Reduction
Parameter
Turbidity
Cysts
Asbestos
Lead at pH 6.5
Lead at pH 8.5
Mercury at pH 6.5
Mercury at pH 8.5
Lindane
Toxaphene
Atrazine
USEPA
MCL
1 NTU**
99.5% Reduction
99% Reduction
0.015 mg/L
0.015 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
S
tandard No. 53: Health Effects
Influent
Challenge Concentration
11 ± 1 NTU***
Minimum 50,000/L
10
7
10
8
fibers/L; fibers >10 micrometers in length
0.15 mg/L ± 10%
0.15 mg/L ± 10%
.006 mg/L ± 10%
.006 mg/L ± 10%
0.002 mg/L ± 10%
0.015 mg/L ± 10%
0.009 mg/L ± 10%
Influent
Average
10.73 NTU
220,000 #/L
155 MF/L
0.153 mg/L
0.150 mg/L
0.006 mg/L
0.006 mg/L
0.002 mg/L
0.015 mg/L
.00873 mg/L
Average
0.36 NTU
<1
<1
<.001
<.001
0.00026
0.0008
0.000025
<0.001
<0.002
Maximum
.049 NTU
<1
<1
<.001
<.001
0.0005
0.0015
0.00007
<0.001
<0.002
Average
97.09%
>99.99%
>99.99%
>99.35%
>99.35%
98.72%
98.72%
98.72%
92.97%
76.99%
Minimum
95.20%
>99.99%
>99.99%
>99.35%
>99.35%
90.91%
75.93%
96.50%
91.67%
75.31%
Min. Required
Reduction
0.5 NTU
>99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.003 mg/L
Effluent % Reduction
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

amana-ac-2224

Suche zurücksetzen

  • Hallo,wieviel Kältemittel ist bei diesem Schrank im System? Eingereicht am 17-7-2020 16:31

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Amana AC 2224 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info