PROTECT THE ENVIRONMENT
e wheelie bin symbols mean that according to local laws
and regulations your product and/or its battery shall be
disposed of separately from household waste. When the
product/battery reaches its end of life take it to a collection
point designated by local authorities. e seperate disposal
and recycling will help conserve natural resources and protect
human health and the environment. Refer to User’s Guide for
removal of batteries.
TECHNICAL SPECIFICATIONS
Range:
Open field (Open area without obstructions):
• Between the Nursery Unit and the Parent Unit: up to 250 meters.
Power Supply:
2 AAA alkaline batteries (not included) or 100/240V AC/5V DC
adapter for Nursery Unit.
2 AAA rechargeable batteries and 100/240V AC/5V DC adapter
for the Parent Unit.
Caution: To reduce the risk of electric shock, do not expose this
product to rain or moisture.
Danger of explosion if batteries are incorrectly replaced. e
battery included for the Parent Unit is 2 AAA NIMH rechargeable
batteries, manufactured by GPI INTERNATIONAL LIMITED
(GN60AAAHC, 1.2V 600mAh). Only use the Angelcare recommended
replacement battery. To obtain information on replacement
batteries please contact Angelcare customer service: www.
angelcarebaby.com or contact your local distributor. Instructions
will be included with the replacement battery. Keep all batteries
away from children.
Batteries:
• DO NOT mix old and new batteries.
DO NOT mix alkaline standard (carbon-zinc), or rechargeable
(NI-CD, NIMH, etc.) batteries.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN
INCORRECT TYPE
Transmission:
Transmission between the Parent Unit and the Nursery Unit is
made on 1.88 to 1.9 GHz frequency for Europe/Asia/Africa/Australia.
Maximum RF Power Transmitted:
24dBm (250mW) between Nursery Unit and Parent Unit
RF Channel no. between Nursery Unit and Parent Unit: 10
Hereby, Angelcare Monitors Inc., declares that this Baby Monitor
is in compliance with Directive 2014/53/EU. e full text of
the EU declaration of conformity is available at the following
internet address: https://international.angelcarebaby.com/
declaration-of-conformity
ErP Compliance
USE ONLY THE FOLLOWING ANGELCARE
®
BRAND POWER SUPPLY MODEL
NUMBERS:
EUROPEAN UNION INCLUDING GERMANY  K05S050060G
UK  K05S050060B
See product for compliance marks specific to this device.
APPENDIX: INFORMATION ON EXPOSURE TO RADIO WAVES AND SAR SPECIFIC ABSORPTION RATE
e design of Parent Unit complies with the current regulations governing exposure to radio waves. ese regulations are based on scientific
guidelines that indicates safety margins designed to ensure the safety of everyone, regardless of age or state of health. e guidelines on
exposure to radio waves use a unit of measurement known as the SAR (Specific Absorption Rate). SAR tests are carried out using standardized
method, with the Parent Unit transmitting at the highest certified level of power on all the frequency bands it uses. e maximum SAR level
recommended by ICNIRP (International Commission on Non Ionizing Radiation Protection) is 2 W/kg, measured on 10 g of tissue. e highest
SAR levels recorded for the Parent Unit are as follows: When used in direct contact with the body 1.8GHz DECT is 0.042W/Kg(10g). When used
in front of the face 1.8GHz DECT is 0.021W/Kg(10g). is device complies with the guidelines on exposure to radio frequency both when it is
positioned at 0mm from the body or in front of the face.
15
E
N
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Angelcare AC110 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info