Technical specifi cations
Video Camera: Full colour CMOS Video Sensor (240 x 320 pixels, 15 fps)
with Infrared Night Vision
Screen: 2.75” LCD full colour digital touch screen
Range: up to 200 metres (655 feet)
Number of Channels: 64 channels
Power Supply: 3 x AAA (LR03) alkaline batteries (not included) or 7.5V AC
adaptor for Nursery Unit. 3 x AAA (LR03) rechargeable batteries (included)
and 7.5V AC adaptor for Charging Base for the Parent Unit.
CAUTION: To reduce the risk of electric shock, do not expose this product
to rain or moisture. Danger of explosion if batteries are incorrectly
replaced. The included batteries are 3 x AAA NIMH rechargeable batteries
manufactured by GPI International Limited, GN60AAAHC, 1.2V 600mAh.
THE SUPPLIED BATTERIES CAN ONLY BE REPLACED BY 3 X AAA NIMH
RECHARGEABLE BATTERIES.
Batteries:
• Do not mix old and new batteries
• Do not mix alkaline, standard (carbon-zinc), or rechargeable (NI-CAD,
NI-MH, etc) batteries
Transmission:
Data transmission between the Parent Unit and Nursery Unit is on the
2.4GHz frequency.
• Sound Function
• Movement Function
• Tic Function
• Sound Transmission
• Sound Transmission - Microphone Sensitivity (if applicable)
• Alarm Type Setting
• Parent Unit Speaker Volume
• SensorPad Sensitivity
• Video Screen - Power Saving Function
• Temperature Scale
• Temperature Alarm
• High Temperature Alarm
• Low Temperature Alarm
• Timer
ON
ON
OFF
Continuous Sound
Level 2 of 4
Sound Alarm
Level 3 of 6
Level 3 of 5
OFF
°Celsius
OFF
30 °Celsius
19 °Celsius
OFF
Factory settings
NEVER use the Angelcare Movement & Sound Monitor (or any
movement monitor) if multiple babies are sleeping together in ONE bed!
For monitoring more than one baby (e.g. twins) you need two Angelcare
Movement & Sound Monitors and the babies need to be in SEPARATE
beds.
If you are using two Angelcare monitors it is essential that:
• Each monitor is set to a different channel
• The distance between the two Nursery Units is at least 1 metre
• The distance between the Parent Units is at least 1 metre
Please see website for more information.
Monitoring more than one baby
RETAIN INSTRUCTIONS: Always keep this Instructions Manual for future
reference.
WATER, MOISTURE AND HEAT DAMAGE: Keep all monitor components
away from water (sink, bath tub, swimming pool) and places that emit heat
(stove, radiator).
VENTILATION: ALWAYS place both units on a fl at surface in an upright
position to ensure free air circulation around the units. The SensorPad is
made of plastic and does not permit the air to circulate. Therefore, mildew
build-up could develop underneath the mattress in the SensorPad area.
We suggest rotating the mattress regularly (as per the manufacturer’s
instructions) to prevent any mildew.
AC POWER SOURCE: Use only the AC adaptors supplied with the Angelcare
Baby Monitor.
WIRES PROTECTION: Avoid damage to the wires of the SensorPad and AC
adaptors. Route wires so that they are not likely to be walked on or pinched
by items placed upon or against them.
CLEANING: Disconnect all units before cleaning. DO NOT immerse in water.
Use a dry cloth to keep monitor free from dust. DO NOT spray with cleaning
products or solvents. Wipe SensorPad with a cloth moistened very slightly
with an antiseptic or mild detergent.
OBJECTS AND LIQUIDS: Always ensure that no objects or liquids are
pushed or spilled into any openings of the Parent Unit, Nursery Unit and/or
SensorPad.
NON-USE PERIODS: When not using the baby monitor for any long period,
remove the batteries from both units and disconnect the AC adaptors from
the mains power.
Maintenance of your Angelcare Baby Monitor
Consumer Helpline: 0845 009 1789 | www.angelcare-uk.co.uk
12
AC1100_Manual.indd 12AC1100_Manual.indd 12 19/5/11 2:39:20 pm19/5/11 2:39:20 pm
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

angelcare-ac1100

Suche zurücksetzen

  • Hallo Support Team! Ich bräuchte bitte die deutsche Bedienungsanleitung von Angelcare AC1100-d. Wäre es möglich die PDF an RomyErtel@web.de zu senden? Eingereicht am 11-10-2019 22:44

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Angelcare AC1100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Angelcare AC1100

Angelcare AC1100 Bedienungsanleitung - Holländisch, Dänisch - 83 seiten

Angelcare AC1100 Bedienungsanleitung - Französisch - 59 seiten

Angelcare AC1100 Bedienungsanleitung - Portugiesisch - 83 seiten

Angelcare AC1100 Bedienungsanleitung - Spanisch - 59 seiten

Angelcare AC1100 Bedienungsanleitung - Polnisch, Schwedisch, Finnisch - 83 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info