537060
15
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
The sound
transmission is
intermittent
The power ON
indicator on the
Nursery Unit does
not light up
There is very weak
reception
There is interference
or noise coming
from the Parent Unit
(e.g. interference
from other monitors,
wireless phones and
networks, walkie-
talkies, etc.)
There is ‘feedback’
coming from the
Parent Unit (loud
howling noise)
The mattress has
become mouldy
There is no video
transmission
The sound transmission is set to Voice Activated
and will only transmit if the microphone on the
Nursery Unit detects a certain level of sound.
The AC adaptors are not connected properly or the
mains socket is out of order or not switched on.
The Nursery unit is not turned ON.
The Parent and Nursery Units are too far apart
and the ‘Out of Range’ indicator is OFF.
One or both units are placed near a large metal
construction which obstructs the transmission.
One or both units are not in the upright position.
The batteries are low.
The Parent Unit is located near motorized devices,
uorescent lights, televisions, etc.
The Parent Unit and the Nursery Unit are too close
together.
There is not enough air circulation under the
mattress.
The video screen has been turned OFF.
The Power Save Function has been activated.
Increase the microphone sensitivity if you would like to keep Voice
Activated sound transmission or activate Continuous Sound transmission.
Please see Step 7 for further instructions.
Check the connections and/or change to another electrical socket.
Press and hold the left wing backwards for 2 seconds to turn ON the
Nursery Unit (see Step 2a).
Reduce the distance between the two units until communication is
established. Ensure both units are ON. Turn the Out of Range function ON
to avoid this in the future (see Step 15).
Reduce the distance between the two units until communication is
established. Ensure both units are ON. Turn the Out of Range function ON
to avoid this in the future (see Step 15).
Place both units on a fl at surface away from baby’s reach.
Check/replace the batteries or recharge the Parent Unit (see Step 3a).
Check if all AC adaptors are working correctly and if the mains socket is
turned ON.
Keep the Parent Unit and the Nursery Unit away from any devices that
can be a source of interference.
Keep the Parent and Nursery Units at least 3 metres/10 feet apart.
Decrease the volume level on the Parent Unit using the UP and DOWN
buttons on the right hand side of the Parent Unit.
If you have placed a large piece of plywood under the SensorPad as
instructed, please drill holes in the plywood to allow air circulation. The
SensorPad is a passive device and does not radiate any form of energy
or heat.
• Press the ON/OFF button on the left hand side of the Parent Unit to
start the video transmission.
• Press the video screen to start the video transmission.
• Deactivate the Power Save Function.
• For further instructions, see Step 9.
Troubleshooting (continued)
Consumer Helpline: 0845 009 1789 | www.angelcare-uk.co.uk
15
AC1100_Manual.indd 15AC1100_Manual.indd 15 19/5/11 2:39:21 pm19/5/11 2:39:21 pm
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

angelcare-ac1100

Suche zurücksetzen

  • Hallo Support Team! Ich bräuchte bitte die deutsche Bedienungsanleitung von Angelcare AC1100-d. Wäre es möglich die PDF an RomyErtel@web.de zu senden? Eingereicht am 11-10-2019 22:44

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Angelcare AC1100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Angelcare AC1100

Angelcare AC1100 Bedienungsanleitung - Holländisch, Dänisch - 83 seiten

Angelcare AC1100 Bedienungsanleitung - Französisch - 59 seiten

Angelcare AC1100 Bedienungsanleitung - Portugiesisch - 83 seiten

Angelcare AC1100 Bedienungsanleitung - Spanisch - 59 seiten

Angelcare AC1100 Bedienungsanleitung - Polnisch, Schwedisch, Finnisch - 83 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info