Hoxton Stove User Guide
BK755 Page 19
7.7 Replacement parts
Genuine replacement spare parts can be obtained from your Arada retailer /dealer.
You can find a complete list of spares and consumables such as liners, replacement grate
parts and throat plates as well as items to enhance its visual appearance and efficiency,
such as stove paint and rope kits.
It is worth noting that the fitting of non-official parts to your stove will invalidate the
guarantee.
7.8 Classification
The Hoxton 7 stove is classed as intermittent operation. Thereby meaning, to give nominal
rated output, you will have to refuel a minimum of 45min for wood as stated in EN
13240:2011 +A2:2004.
7.9 Adverse weather conditions
If due to adverse weather conditions your stove does not operate correctly and causes the
stove to emit smoke do not treat it as a nuisance, this smoke will indicate that
carbon-monoxide is being emitted into the room. Extinguish the stove by reducing the firing
rate, open windows and allow the stove’s fuel to burn out before closing the windows. The
probable cause is insufficient draw—check flue ways and have the chimney tested for flue
pressure.
Ashpan
Fig. 7. Ash Pan & Operating Tool
Operating Tool