C31/P38/P1
E-12
English
C31/P38/P1
E-13
Bi-wiring
Bi-wiring is performed in the same way as single
wiring except that, for each speaker, a pair of cables
are used to connect the ampli er to each speaker.
Follow the instructions given for single wiring; then
perform the same actions, this time connecting the
second set of speaker terminals (labelled “SP2” on
the P38) to the speaker terminals labelled ‘HF’ or
‘High Frequency’. Please refer to the illustration.
Speakers that support bi-wiring have a strip of
metal on the speakers connecting the low-frequency
terminals to those for the higher-frequencies; this
must be removed in a bi-wired system.
Bi-amping
Bi-amping requires the use of a two ampli ers per
channel: either two P38’s or four P1’s in a stereo
system. One P38 (or two P1’s) is/are used to drive
the high-frequency (treble) speakers, the other is
used for the lower (bass) frequencies.
For the P38’s, connect one P38 to the speakers
as described for single wiring, with the exception
that the P38 should be connected to the speaker
terminals labelled ‘HF’ or ‘High Frequency’. Then (in
the same way), connect the second P38 to the low-
frequency terminals. Please refer to the illustration.
For the P1’s: four P1 ampli ers are required for
bi-amping two speakers. Two of the P1’s are used
to drive high-frequency (treble) and two are used
for the lower (bass) frequencies. Decide which
ampli er is to drive which speaker element, then
connect the ampli er to the speaker following the
instructions given for single wiring.
Note that the strip of metal on the speakers
connecting the lower terminals to the upper
terminals must be removed. Failure to do so will
result in damage to both ampli ers, which will not
normally be covered under warranty.
Notes on making speaker connections
n
Do not make any connections to any ampli er while it is switched on. We recommend that your
ampli er is completely disconnected from the mains supply before starting.
n
Before switching your ampli er(s) on for the  rst time after connecting to speakers, please check
all connections thoroughly. Ensure that bare wires or cables are not touching each other or the
ampli er’s chassis (which could cause short circuits), and that you have connected positive (+) to
positive and negative () to negative. Be sure to check the wiring for both the ampli er and the
speaker.
n
After making connections: switch the ampli er(s) on, select a source signal, then gradually increase
the volume to the required listening level.
n
If you are unsure as to how your system should be connected, or need advice on bi-wiring or bi-
amping, please contact your Arcam dealer who will be happy to help you.
Connecting to a power supply
Mains lead
Your ampli er is normally supplied with a moulded mains plug already  tted to the lead. Check that the
plug  ts your supply and that your mains supply voltage agrees with the voltage setting (115V or 230V)
indicated on the rear panel of the unit before plugging in.
If your mains supply voltage or mains plug is different, please consult your Arcam dealer immediately.
Plugging in
Push the IEC-plug of the power cable into the socket POWER INLET on the back of the unit, making sure
it is pushed in  rmly.
Stand-by power
For remote stand-by operation, the ampli er’s control power supply is kept powered-up all the time the
unit is connected to the mains supply. The front-panel power-switch powers down all other circuitry and
power consumption in this mode is less than 2W.
This means that even though the power switch is off, it may be possible to hear a slight residual hum
coming from the mains transformer inside the ampli er. This is perfectly normal. If the unit is to be left
unused for an extended period, however, we recommend that it is disconnected from the mains supply.



A P38 connected to speakers using bi-wiring.




A P38 connected to speakers using bi-amping.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Arcam P1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Arcam P1

Arcam P1 Bedienungsanleitung - Deutsch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info