765021
33
Zoom out
Zoom in
Vorherige Seite
1/124
Nächste Seite
Quick Reference Guide
Starting Pump 1
Press Pump 1 button to turn on at low speed. Press a second time
to turn Pump 1 to high speed. A third time turns the Pump 1 off. A
built in timer automatically turns Pump 1 off after 20 minutes,
unless it has been manually deactivated.
The Pump 1 indicator lights up when Pump 1 is on high speed and
flashes when Pump 1 is on Low speed.
Starting Pump 2
Press Pump 2 button to turn on Pump 2. Press a second time
turns Pump 2 off. A built in timer automatically turns Pump 2 off
after 20 minutes, unless it has been manually deactivated.
The Pump 2 indicator lights up when Pump 2 is on high speed.
Starting Pump 3
Press Pump 3 button to turn on Pump 3. Press a second time
turns Pump 3 off. A built in timer automatically turns Pump 3 off
after 20 minutes, unless it has been manually deactivated.
The Pump 3 indicator lights up when Pump 3 is on high speed.
Starting SDS
Press SDS button to turn on SDS. Press a second time turns SDS
off. A built in timer automatically turns SDS off after 20 minutes,
unless it has been manually deactivated SDS.
Setting Water Temperature
Use the Up or Down Arrow button to regulate water temperature.
The temperature setting will be displayed for 5 seconds to confirm
your new selection.
Water temperature can be adjusted by 1˚ increments from 59˚F to
104˚F (15˚C to 40˚C). The temperature symbol indicates the
desired temperature, NOT the current water temperature.
Automatic Water Heater Start
When water temperature is 1ºF (0.5ºC) lower than the Set Point,
the water will automatically turn on & heat until the water tempera-
ture reaches 1ºF (0.5ºC) above the Set Point.
The Heater indicator lights up when the heater is on.
Spa Boy® Boost (if equipped)
Press and hold the Pump 2 key for 10 seconds to initiate Spa
Boy® Boost which runs the Spa Boy®electrode for 30 minutes
regardless of the ORP setting. When activeted “Sbb” will be
displayed.
Temperature Unit
Press and hold the light button for 5 seconds to toggle between ˚F
and ˚C.
Turning The Lights On
If your spa is equipped with an original lighting package, you can
toggle through the color options by pressing the Light button
on/off. Press Light button to turn on. Press a second time to turn
lights off. A built in timer will automatically turn the lights off after
2 hours unless it has been deactivated. The Light indicator is
displayed when the lights are on.
Boost Mode
Press and hold Pump 2 button for 10 seconds to enable Boost
Mode. In this mode, Pump 1 high speed and the ozonator will run
for 45 minutes. When this is enabled, “boo” is displayed on the
control Pad. This mode is used to speed up filtration after inten-
sive use of the spa or to help chemicals just added to the spa.
Pressing any button will exit Boost Mode.
Fogger Waterfall
The Fogger Waterfall is controlled by pressing and holding the
Light Button for 2 seconds. This will activate the Lights, Fogger
and the small Pump that operates the system. Pressing the “Light
Button once will turn the Fogger/Waterfall off. The system will stay
activated for 2 hours unless it has been manually turned off using
the Light button.It is advisable on first start up or restart that water
is put into the opening of the Fogger/Waterfall to fill up the area to
prevent premature damage to the Fogger unit.
Owners Manual - Custom Series
3333
33

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Arctic Spas Grizzly wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info