765004
40
Zoom out
Zoom in
Vorherige Seite
1/124
Nächste Seite
Outside
Dimensions Height Heater
(watts)
Water
Capacity
Dry
Weight
Electrical
Requirements
North America
A = actual / B = breaker
Electrical
Requirements
Europe
Mustang 93’’ x 93’’
235 x 235 cm
39’’
98 cm
NA / Euro
4000 W
370 Gallons
1400 Liters
973 Lbs
441 Kg
240 Volts / 6 Gauge Wire
1 Pump / A32amp / B40amp
2 Pumps / A40amp / B50amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1 phase x 32 Amp
or
3 phase x 16 Amp
McKinley 93’’ x 93’’
235 x 235 cm
39’’
98 cm
NA / Euro
4000 W
449 Gallons
1700 Liters
951 Lbs
431 Kg
240 Volts / 6 Gauge Wire
1 Pump / A32amp / B40amp
2 Pumps / A40amp / B50amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1Øx32 Amp
3Øx16 Amp
Totem 85’’ x 85’’
217 x 217 cm
41’’
104 cm
NA / Euro
4000 W
360 Gallons
1360 Liters
735 Lbs
333 Kg
240 Volts / 6 Gauge Wire
1 Pump / A32amp / B40amp
2 Pumps / A40amp / B50amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1 phase x 32 Amp
or
3 phase x 16 Amp
Eagle 85’’ x 85’’
217 x 217 cm
41’’
104 cm
NA / Euro
4000 W
313 Gallons
1885 Liters
741 Lbs
336 Kg
240 Volts / 6 Gauge Wire
1 Pump / A32amp / B40amp
2 Pumps / A40amp / B50amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1 phase x 32 Amp
or
3 phase x 16 Amp
Timberwolf 69’ x 85’’
174 x 217 cm
39’’
98 cm
NA / Euro
4000 W
234 Gallons
884 Liters
611 Lbs
277 Kg
240 Volts / 6 Gauge Wire
1 Pump / A32amp / B40amp
2 Pumps / A40amp / B50amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1 phase x 32 Amp
or
3 phase x 16 Amp
Athabascan 172’’ x 93’’
436 x 236 cm
51’’
129 cm
NA / Euro
5500 / 2x3600
1347 Gal-
lons
5100 Liters
1910 Lbs
866 Kg
240 Volts / 6 Gauge Wire
1 Pump / A32amp / B40amp
2 Pumps / A40amp / B50amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1 phase x 32 Amp
or
3 phase x 16 Amp
Hudson 172’’ x 93’’
436 x 236 cm
51’’
129 cm
NA / Euro
5500 / 2x3600
1347 Gal-
lons
5100 Liters
1910 Lbs
866 Kg
240 Volts / 6 Gauge Wire
1 Pump / A32amp / B40amp
2 Pumps / A40amp / B50amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1 phase x 32 Amp
or
3 phase x 16 Amp
Kingsher 172’’ x 93’’
436 x 236 cm
51’’
129 cm
NA / Euro
5500 / 2x3600
1347 Gal-
lons
5100 Liters
1910 Lbs
866 Kg
240 Volts / 6 Gauge Wire
2 Pumps / A48amp / B60amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1Øx32 Amp
3Øx16 Amp
Wolverine 172’ x 93’’
436 x 236 cm
51’’
129 cm
NA / Euro
5500 / 2x3600
1347 Gal-
lons
5100 Liters
1910 Lbs
866 Kg
240 Volts / 6 Gauge Wire
3 Pumps / A48amp / B60amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp
1Øx32 Amp
3Øx16 Amp
Owners Manual - Classic Series
Specications
4040
40

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Arctic Spas Klondiker wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info