EG
SAFETY INSTRUCTIONS
l
Read this booklet carefully before using this air
conditioner. If you still have any difficulties or
problems, consult your dealer for help.
l
This air conditioner is designed to give you
comfortable room conditions. Use this only for its
intended purpose as described in this Instruction
Manual.
l
Never use or store gasoline or other flammable vapor or
liquid near the air conditioner. It is very dangerous.
l
Never install electrical equipment, which is not
protected with IPX1 protection (protection against
vertical water drop), under the unit.
l
The manufacturer assumes no responsabilities if the
safety regulations or local codes are not observed.
l
Never use the power main switch to start or stop the
air conditioner: always use the ON/OFF button on the
remote control unit or the selector switch on the unit.
l
Do not let children play with the air conditioner.
l
Do not cool the room too much if babies or invalids
are present.
l
This air conditioner is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the air conditioner
by a person responsible for their safety.
WARNING
CAUTION
INSTALLATION LOCATION
l
We recommend this air conditioner to be installed
properly by qualified installation technicians in
accordance with the installation instructions
provided with the unit.
l
Do not install this air conditioner where there are
fumes or flammable gases, or in an extremely humid
space such as a green house.
l
Do not install the air conditioner where excessively
high heat-generating objects are placed.
l
Do not install the air conditioner where the
atmosphere is extremely damp or humid (e.g.
greenhouse or laundry) it could be wetted by drops
of water (i.e. in laundries).
l
To protect the air conditioner from heavy corrosion,
avoid installing the outdoor unit where salty sea
water can splash directly onto it or in sulphurous
air near a spa.
WARNING
ELETRICAL REQUIREMENTS
l
Before installation, check that the voltage of the electric
supply in your home or office is the same as the voltage
shown on the nameplate.
l
All wiring must conform to the local electrical codes.
Consult your dealer or a qualified electrician for details.
l
Each unit must be properly grounded with a ground (or
earth) wire or through the supply wiring.
l
Wiring must be done by a qualified electrician.
HOW TO INSTALL BATTERIES
l Remove trhe lid in the rear part of the remote control
unit and check the settings of the four microswitches
as shown below:
TEMPERATURE SENSOR SELECTOR
l
Under normal conditions the room temperature is
detected and checked by the temperature sensor placed
in the remote controller (I FEEL icon displayed ).This
function is designed to provide a comfortable room
temperature by transmitting the temperature control
command from the location next to you. When using this
function, the remote, control should always be pointed
at the air conditioner, therefore it should be placed in
a position in which it is visible by the indoor unit (for
example, do not put it in a drawer).
l
It is possible to disable the remote controller room
sensor pressing the I FEEL button. In this case the I
FEEL icon on the remote controller display lights off and
only the sensor placed in the air conditioner becomes
active.
USING THE REMOTE CONTROL UNIT
l
Insert two AAA alkaline batteries of 1,5 V-DC making
sure that point in the direction marked in the battery
compartment.The displayed time flashes.
Press the SEL TYPE button.
Remote controller is now ready for operation.
l
The batteries last average more than six months,
anyway it depends on how much you use the remote
control unit.
Remove the batteries if you do not use the remote
control unit for more than one month.
Replace the batteries when the remote control unit
lamp fails to light, or when the air conditioner does not
receive the remote control unit signals.
l
The batteries of the remote control contain polluted
substances. Exhausted batteries must be disposed
according to the laws in force.
OPERATION WITH THE REMOTE CONTROL UNIT
When using the remote control unit, always point the unit
transmitter head directly at the air conditioner receiver.
HOW TO TURN ON THE AIR CONDITIONER
Press the ON/OFF button to turn the air conditioner on.
The operation lamp will light up, indicating the unit is in
operation.
The remote control unit transmits signals to the
indoor unit each time you press a key and at any
temperature change detected by the IFEEL sensor. In
case of troubles (low batteries, remote control placed
in a position not visible by the indoor unit,...) room
temperature control is automatically switched to the
sensor of the indoor unit. In this case, the temperature
around the remote control unit may differ from the
temperature detected in the air conditioner position.
NOTE
SWITCHES
NOTE
IF YOU INSTALL MORE THAN ONE INDOOR
UNIT IN THE SAME ROOM:
It is possible to utilise only one remote control for all
the units.
On the contrary, if you want to address each remote
control to its unit, follow the procedure”Remote control
unit/indoor unit address” (see Installation Instructions).
PLEASE, SEE THE END
OF THIS MANUAL FOR
DETAILS
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Argo ADIBS13DC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Argo ADIBS13DC

Argo ADIBS13DC Installationsanweisung - Deutsch - 76 seiten

Argo ADIBS13DC Bedienungsanleitung - Deutsch - 15 seiten

Argo ADIBS13DC Installationsanweisung - Englisch, Französisch - 76 seiten

Argo ADIBS13DC Bedienungsanleitung - Französisch - 15 seiten

Argo ADIBS13DC Installationsanweisung - Italienisch, Portugiesisch, Spanisch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info