FILTER BUTTON “CLEAN FILTER SYSTEM”: after 250 hours of operation, the
FILTER RESET led turns on to indicate that it is time to clean the filter. Take the filter
out and clean it. Then press the FILTER button.
RELATIVE HUMIDITY ADJUSTER BUTTON: the humidity can be set from 35% to
80% in 5% steps with the + and - buttons, or you can set the appliance to continuous
drain (CO) – maximum dehumidification.
LED
RUNNING LED
The dehumidifier is working.
FULL LED
When the tank is full, the TANK FULL LED comes on and the appliance stops running. A 10 second beep sounds.
Remove the tank and empty it (as indicated in "HOW TO ELIMINATE CONDENSATION"), the restore it; the dehumidifier
will start running again.
CONTINUOUS LED
Shows that the dehumidifier is running in continuous mode.
CLEAN FILTER LED
Indicates that the filter must be cleaned.
DEFROST: the dehumidifier is designed to operate at ambient temperatures from + 5°C to + 32°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues running.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
AUTO RESTART: the dehumidifier starts up again after a power failure.
MEMORY FUNCTION: the dehumidifier maintains its settings during a power failure.