665483
27
Zoom out
Zoom in
Vorherige Seite
1/30
Nächste Seite
EG
27
To enter the conguration menu, with Emix already on, press and hold the BUTTON 9 for about 7 seconds.
When only the RED LED lights up, keep BUTTON 9 pressed until the BLUE LED lights up. At this point release BUTTON 9.
After 5 seconds without any operation, Emix exits the conguration procedure and returns to the previous menu.
Booster mode setting
The use of electrical heating elements installed in a storage tank or in a electrical water heater allows you to heat the cold
water faster, to reach the desired water temperature even in conditions of very low external temperatures or to heat the
water even if the heat pump is switched off for maintenance.
When you activate the Booster mode, the software will automatically handle the electrical heaters.
If after 120‘ from start up of the system (the time counter starts when the Booster mode is set), the water setpoint is not
reached, the rst electrical element is automatically activated. The other elements, one by one, will be activated every
120‘ following the course of the water temperature, until reaching the setpoint.
To activate / deactivate the Booster mode, from the conguration menu, quickly press BUTTON 9 until the only BLUE
LED is ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press BUTTON 9 once more.
3 consecutive beeps conrm the setting.
NOTE
By default, the Booster mode is off.
Super Booster mode setting
When the Super Booster mode is activated, all the connected electrical heaters will be activated at the same time, to-
gether with the heat pump.
When the setpoint is reached, all electrical heaters are switched off and the Super Booster mode is automatically turned
off.
To activate / deactivate the Super Booster mode, from the conguration menu, quickly press BUTTON 9 until the only
RED LED is ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press BUTTON 9 once more.
3 consecutive beeps conrm the setting.
NOTE
By default, the Super Booster mode is off.
EMIX CONFIGURATION
Setpoint limit setting with Heat Pump
It is possible to set the maximum achievable setpoint when the Heat Pump is working only for Emix. This limit can be set
to 50°C or 58°C.
To change the setting, from the conguration menu, quickly press BUTTON 9 until the BLUE and YELLOW LEDs are
ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press BUTTON 9 once more.
3 consecutive beeps conrm the setting.
NOTE
By default the limit is set to 50°C. We recommend to keep this setting to preserve the Emix performance.
Antilegionella cycle setting
To activate / deactivate the Antilegionella cycle, from the conguration menu, quickly press BUTTON 9 until the only YEL-
LOW LED is ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press BUTTON 9 once more.
3 consecutive beeps conrm the setting.
NOTE
By default, the Antilegionella cycle is on. It is highly recommended to keep it enabled.
For details on the operation of the Antilegionella cycle, see section “ANTILEGIONELLA CYCLE”.
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Argo Emix Tank wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Argo Emix Tank

Argo Emix Tank Bedienungsanleitung - Deutsch - 29 seiten

Argo Emix Tank Bedienungsanleitung - Englisch - 29 seiten

Argo Emix Tank Bedienungsanleitung - Französisch - 29 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info