3
BEFORE USING THE APPLIANCE
● Check that the power supply at the location where the air conditio-
ner is going to be used is 220-240V ~ 50Hz
● Make sure that the electrical installation is suitable to supply conti-
nuosly current necessary for the air conditioner in addition to that
already used by other electric appliances (white goods, lighting).
See the max electric imput indicated on the name plate positioned
on the air conditioner.
● The installation of a double-pole switch, protected by 10 A fuses of
the delayed type, upstream the electricity wall soket, is recommen-
ded.
● The unit has to be connected according to the local electrical rules.
● Make sure that circuit breakers, fuses, etc, are of sufficient capa-
city to handle a start-up current of 35 A (generally less then 1
second).
● Do not install the air conditioner where it could be wetted by drops
of water (i.e. in laundries).
● Make sure that the ON - OFF push-button switch on the control
panel of the air conditioner is in OFF position.
● Before connecting the air conditioner to a power socket, make sure
that the socket is provided with an earth connection in compliance
with local codes.
● Never use the power plug as a mean to start or stop the air condi-
tioner: always use the ON/OFF push-button switch on the air con-
ditioner control panel.
● WARNING!
Do not stick anything into the air outlet of the air conditioner.
This is very dangerous because the fan is rotating at high speed.
● WARNING!
The air conditioner is provided with a time-guard system, which
does not allow re-starting of compressor until after 3 minutes from
a previous stop. So avoid quick movements of the thermostat knob
in both directions when compressor is running.
● Make sure that there are no obstacles around the indoor unit affec-
ting the free circulation of air. Do not block the air intake and outlet
of the unit with curtains or other.Never put objects on the top of the
unit.
● The manufacturer assumes no responsabilities if the safety regula-
tions or local codes are not observed.
IMPORTANT ADVICE
1.When you move the air conditioner around your house, hang the
outdoor unit to the rear of the indoor unit. Be careful not to twist nor
kink the flexible tube.
2.When you move the outdoor unit, always hold it by the handle,
never pull it by the flexible tube.
3.Never let the outdoor unit hang on the flexible tube.
4.When you recover the outdoor unit after operation, drain away any
remaining condensate by tilting the unit.
EG
● Always unplug the unit from the power socket before moving or clea-
ning it.
● Some edges and the condenser fins are sharp and may cause injury
if handled improperly; special care should be taken when you clean
these parts.
WARNING
LIMIT OF ELEVATION
DIFFERENCE
1000
INDOOR UNIT
NO!
NO!