This air conditioner is equipped with cooling, drying and fan functions.
Details on these functions are provided here following; refer on these descriptions when using the air conditioner.
NOTE
EG
3
COOLING
OUTDOOR TEMPERATURE 46°C D.B.
ROOM TEMPERATURE 32°C D.B./23°C W.B.
OUTDOOR TEMPERATURE 19°C D.B.
ROOM TEMPERATURE 19°C D.B./14°C W.B.
OPERATING LIMITS
MAXIMUM CONDITIONS
MINIMUM CONDITIONS
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
–Low voltage no. 2006/95/EC.
(Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010
+ A15:2011).
–Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC.
(Standard: EN55014-1 (2006) +
A1(2009) + A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
–RoHS2 no.2011/65/EU.
–Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
–Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation
and/or operating instructions.
Before using the appliance
l Check that the power supply at the location where the
air conditioner is going to be used is 220/240 volt, single
phase.
l For your safety care check periodically the conditions of
the electric supply cable; the electrical connection of the
unit is Y type with cable prepared in a special way; in
case you should notice any damage due to usage, call the
nearest After Sale Service to get the cable replaced.
l Before connecting the air conditioner to a power
socket, make sure that the socket is provided with
an earth connection.
l Verify that the available power supply is sufficient for
running other electrical domestic appliances in use
simultaneously from the same supply. See the data plate
on the unit showing the max. absorbed powers.
l Install a double - pole switch, protected fuses of the
delayed type, upstream the electricity wall socket 10A.
ELECTRICAL REQUIREMENTSINSTALLATION LOCATION
l Do not install this air conditioner where there are
fumes or flammable gases, or in an extremely humid
space such as a green house.
l Do not install the air conditioner where excessively
high heat-generating objects are placed.
l Do not install the air conditioner where the
atmosphere is extremely damp or humid (e.g.
greenhouse or laundry) it could be wetted by drops
of water (i.e. in laundries).
Avoid:
To protect the air conditioner from heavy corrosion, avoid
installing the outdoor unit where salty sea water can splash
directly onto it or in sulphurous air near a spa.
l Make sure that there are no obstacles around the
indoor unit affecting the free circulation of air. Do not
block the air intake and outlet of the unit with
curtains or other.Never put objects on the top of the
unit.
WARNING
l Make sure that circuit breakers, fuses, etc. are of sufficient
capacity to handle start - up current (normally for no longer
than a second).
l All wiring must conform to the local electrical codes.
Consult your dealer or a qualified electrician for details.
WARNING!
The air conditioner is provided with a time-guard system,
which does not allow re-starting of compressor until after
3 minutes from a previous stop.