724565
12
Zoom out
Zoom in
Vorherige Seite
1/15
Nächste Seite
12
EN
The use of portable telephones near the air-conditioner
may cause disturbance to its normal operation and
must be avoided. In case abnormal operation is noticed,
(OPERATION lamp lights but outdoor unit will not run)
to restore normal operation turn-off electric supply for
60 seconds at least, by disconnecting the main switch
or the wall plug, then start again the air-conditioner.
The blinking OPERATION lamp, together with the stop
of the air conditioner for a short time are due to the
exceeding condensate drainage.
If the OPERATION lamp goes on blinking and the air
conditioner definitely stops means that the condensate
pump is not working or that the condensate drain pipe
in the flexible connection pipe is obstructed; in this case
contact the AFTER SALE SERVICE.
In case of emergency the air conditioner can work by
draining the condensate from the back little pipe into a
rather short container: extract the little pipe and remove
the cap.
If your air conditioner does not work properly, first check
the following points before requesting service.
If it still does not work properly, contact your dealer or
service center.
TIPS FOR ENERGY SAVING
DO NOT:
Block the air intake and outlet of the unit.
If they are obstructed, the unit will not work well, and
may be damaged.
Let direct sunlight into the room. Use sunshades, blind
or curtain.
DO:
Always try to keep the air filter clean. A clogged filter
will impair the performance of the unit.
To prevent conditioned air from escaping, keep
windows, doors and any other openings closed.
TROUBLESHOOTING
Trouble: the air conditioner does not run at all.
Possible cause:
1. Power failure.
2. Leakage breaker tripped.
3. Line voltage is too low.
4. Operation button is OFF.
5. Batteries in remote control unit have run down.
Remedy:
1. Restore power.
2. Contact service center.
3. Consult your electrician or dealer.
4. Press the button again.
5. Replace batteries.
Trouble: Compressor runs but soon stops.
Possible cause:
1. Obstruction in front of condenser coil.
Remedy:
1. Remove obstruction.
Trouble: Poor cooling performance.
Possible cause:
1. Dirty or clogged air filter.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. Thermostat is set too high.
Remedy:
1. Clean air filter to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the temperature lower.
Trouble: Clicking sound is heard from the air conditioner.
Possible cause:
1. Any plastic parts may expand or shrink due to a sudden
temperature change. In this event, a clicking sound may
occur.
Remedy:
1. This is normal, and the sound will disappear when an
even temperature is settled.
NOTE
The fixed OPERATION lamp and the blinking of TIMER and
STANDBY lamps, indicates that the operating mode selected
( ) is not compatible with the unit. If this happen the
air conditioner does not operate until the correct mode is
selected.
LEDS
POSSIBLE CAUSE REMEDY
STANDBY OPERATION TIMER
FFODefective indoor air sensor Contact service centre
OFFDefective indoor air coil sensor Contact service centre
FOODefective compressor discharge temperature sensor Contact service centre
F
O Mulfunctioning of electronic PCB (current protection) Contact service centre
FO
Mulfunctioning of electronic PCB (temperature protection) Contact service centre
F
••
Mulfunctioning of PFC (power factor correction system) Contact service centre
OFOMulfunctioning of the condensate drainage system Contact service centre
AUTO-DIAGNOSIS
O = LED OFF
= LED ON
F = Flashing LED
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

argo-ulisse-eco

Suche zurücksetzen

  • Beim Abbau der Ausseneinheit tritt Kühlmittel . Was kann ich dagegen machen Eingereicht am 14-9-2021 11:48

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Argo ULISSE ECO wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Argo ULISSE ECO

Argo ULISSE ECO Bedienungsanleitung - Deutsch - 15 seiten

Argo ULISSE ECO Bedienungsanleitung - Französisch - 15 seiten

Argo ULISSE ECO Bedienungsanleitung - Italienisch - 16 seiten

Argo ULISSE ECO Bedienungsanleitung - Portugiesisch - 16 seiten

Argo ULISSE ECO Bedienungsanleitung - Spanisch - 16 seiten