Distanzadall’ostruzione Distance from obstruction
Almeno 300 cm At least 300 cm
Distanza dal pavimento Distance from floor
Almeno 250 cm At least 250 cm
Distanzadall’ostruzione Distance from obstruction
Almeno 50 cm At least 50 cm
Distanzadall’ostruzione Distance from obstruction
Almeno 30 cm At least 30 cm
Distanzadallaparete Distance from wall
Almeno 30 cm At least 30 cm
Distanzadall’ostruzione Distance from obstruction
Almeno 200 cm At least 200 cm
Tubo di scarico Drain pipe
Distanzadall’ostruzione Distance from obstruction
Almeno 50 cm At least 50 cm
INSTALLATION WARNINGS
WARNING: Make sure that the power supply is disconnected before carrying out any work on
the unit.
WARNING: Wear appropriate personal protective equipment before carrying out any work on
the unit.
WARNING: The appliance must be reinstalled in accordance with national system regulations.
WARNING: Wiring and installation must only be performed by a qualified technician trained to
install, modify, extend and service the unit and perform safety and functionality tests.
WARNING: Install a device, master switch or electric plug that will allow all the power from the
appliance to be switched off.
The following information is essential for correct unit installation. However, the installer
should use his or her experience to install the unit according to specific requirements.
Do not install the unit in locations where there are flammable gases or acid or alkaline
substances that may irreparably damage the copper-aluminium heat exchangers or internal
plastic components.
Do not install the unit in offices or kitchens where oil vapours mixed with treated air may
settle on the exchange coils, reducing performance, or on the unit's internal parts, damaging
the plastic components.
Choosing a location for installation
Essential requirements Indoor unit
Do not install the unit in the following locations.
Otherwise, a fault may occur.
Locations with extreme heat sources or
flammable or explosive gases or vapours.
1. Locations with high-frequency devices (e.g.
welding machines, medical equipment).
2. Locations close to coastal areas.
3. Locations with oils or fumes in the air.
4. Locations with sulphide gas.
5. Other locations that have special conditions.
Do not operate the unit in the immediate vicinity
of laundrettes, bathtubs, showers or swimming
pools.
1. There should be no obstructions near the air inlet
or outlet.
2. Choose a location where the condensate can
drain out easily without causing a nuisance.
3. Choose a convenient location to connect the
outdoor unit to the power outlet.
4. Choose a location out of the reach of children.
5. The site should be strong and solid enough to
support the weight of the indoor unit and prevent
noise or vibration.
6. The unit should be installed 2.5 m from the floor.
7. Do not install the indoor unit directly above
electrical equipment.
8. Try to keep a certain distance from fluorescent
lights.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Argo Wall Dual 12000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Argo Wall Dual 12000

Argo Wall Dual 12000 Bedienungsanleitung - Deutsch - 34 seiten

Argo Wall Dual 12000 Bedienungsanleitung - Französisch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info